2021
DOI: 10.1007/s00066-021-01759-4
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric comparison of volumetric modulated arc therapy (VMAT) and high-dose-rate brachytherapy (HDR-BT) for superficial skin irradiation with significant curvature in one or more planes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…Critical organs at risk can be shielded using multi‐leaf collimators and steep dose gradients without compromising the coverage of the planning target volume. 9 Incomplete resections or mutilating surgery of cSCC in the face are not justified because cSCC are highly radiosensitive tumors. 1 Even large tumors can be cured with definitive radiotherapy.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Critical organs at risk can be shielded using multi‐leaf collimators and steep dose gradients without compromising the coverage of the planning target volume. 9 Incomplete resections or mutilating surgery of cSCC in the face are not justified because cSCC are highly radiosensitive tumors. 1 Even large tumors can be cured with definitive radiotherapy.…”
Section: Discussionmentioning
confidence: 99%
“…Pretreatment imaging and VMAT allow high‐precision delivery of radiotherapy to the tumor while sparing normal tissue. Critical organs at risk can be shielded using multi‐leaf collimators and steep dose gradients without compromising the coverage of the planning target volume 9 . Incomplete resections or mutilating surgery of cSCC in the face are not justified because cSCC are highly radiosensitive tumors 1 .…”
Section: Discussionmentioning
confidence: 99%
“…The majority of studies on prostate showed superiority of BT over EBRT for rectal and bladder dose. The skin was the only site where the VMAT plans were better for almost all parameters [ 62 , 63 , 65 , 66 , 70 ]. The thin, large-curvature target volume appears to be better irradiated by external beams.…”
Section: Discussionmentioning
confidence: 99%
“…Six studies have been published on the dosimetric comparison of surface mould HDR-BT and VMAT for the treatment of skin lesions on the scalp and the extremities [62][63][64][65][66][67]. Boman et al [63] used four and three plans of patients treated with HDR-BT surface mould on the scalp and lower leg, respectively, and retrospectively created VMAT plans with the PTV created on the CTV of BT plans with an additional 3-mm setup margin.…”
Section: Skinmentioning
confidence: 99%
See 1 more Smart Citation