2019
DOI: 10.1002/acm2.12757
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Dosimetric comparison of three‐dimensional conformal radiotherapy and intensity‐modulated radiotherapy for left‐sided chest wall and lymphatic irradiation

Abstract: IntroductionThe aim of this study was to compare five different techniques for chest wall (CW) and lymphatic irradiation in patients with left‐sided breast carcinoma.MethodsThree‐dimensional conformal radiotherapy (3DCRT), forward‐planned intensity‐modulated radiotherapy (FP‐IMRT), inverse‐planned IMRT (IP‐IMRT; 7‐ or 9‐field), and hybrid IP‐/FP‐IMRT were compared in 10 patients. Clinical target volume (CTV) included CW and internal mammary (IM), supraclavicular (SC), and axillary nodes. Planning target volume… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
12
6
3
1

Citation Types

0
18
0
0

Year Published

2020
2020
2026
2026

Publication Types

Select...
16
2

Relationship

0
18

Authors

Journals

citations

Cited by 17 publications

(18 citation statements)
references

References 30 publications

0
18
0
0
Order By: Relevance
How this paper cites the one you are viewing
“…61,62 The hybrid RT results obtained indicate that the quality of treatment plans can be increased with the hybrid techniques used. 10,6165 Hybrid techniques are mostly created with the combination of 2D/3D-CRT + IMRT 31,3742,4557 or 2D/3DCRT + VMAT 47,51,55,56 or IMRT + VMAT. 4244…”
Section: Discussion
mentioning
confidence: 93%
“…Using the hybrid technique, the advantages of the 2 RT techniques can be combined and promising results can be obtained. 61,62 The hybrid RT results obtained indicate that the quality of treatment plans can be increased with the hybrid techniques used. 10,[61][62][63][64][65] Hybrid techniques are mostly created with the combination of 2D/3D-CRT + IMRT 31,[37][38][39][40][41][42][45][46][47][48][49][50][51][52][53][54][55][56][57] or 2D/3DCRT + VMAT 47,51,55,56 or IMRT + VMAT.…”
Section: Discussion
mentioning
confidence: 94%
“…61,62 The hybrid RT results obtained indicate that the quality of treatment plans can be increased with the hybrid techniques used. 10,[61][62][63][64][65] Hybrid techniques are mostly created with the combination of 2D/3D-CRT + IMRT 31,[37][38][39][40][41][42][45][46][47][48][49][50][51][52][53][54][55][56][57] or 2D/3DCRT + VMAT 47,51,55,56 or IMRT + VMAT. [42][43][44] Many studies show that the H-IMRT technique used in breast RT is dosimetrically superior.…”
Section: Discussion
mentioning
confidence: 94%
See 2 more Smart Citations
How this paper cites the one you are viewing
“…61,62 The hybrid RT results obtained indicate that the quality of treatment plans can be increased with the hybrid techniques used. 10,6165 Hybrid techniques are mostly created with the combination of 2D/3D-CRT + IMRT 31,3742,4557 or 2D/3DCRT + VMAT 47,51,55,56 or IMRT + VMAT. 4244…”
Section: Discussion
mentioning
confidence: 93%
“…Using the hybrid technique, the advantages of the 2 RT techniques can be combined and promising results can be obtained. 61,62 The hybrid RT results obtained indicate that the quality of treatment plans can be increased with the hybrid techniques used. 10,[61][62][63][64][65] Hybrid techniques are mostly created with the combination of 2D/3D-CRT + IMRT 31,[37][38][39][40][41][42][45][46][47][48][49][50][51][52][53][54][55][56][57] or 2D/3DCRT + VMAT 47,51,55,56 or IMRT + VMAT.…”
Section: Discussion
mentioning
confidence: 94%
“…61,62 The hybrid RT results obtained indicate that the quality of treatment plans can be increased with the hybrid techniques used. 10,[61][62][63][64][65] Hybrid techniques are mostly created with the combination of 2D/3D-CRT + IMRT 31,[37][38][39][40][41][42][45][46][47][48][49][50][51][52][53][54][55][56][57] or 2D/3DCRT + VMAT 47,51,55,56 or IMRT + VMAT. [42][43][44] Many studies show that the H-IMRT technique used in breast RT is dosimetrically superior.…”
Section: Discussion
mentioning
confidence: 94%
See 1 more Smart Citation
How this paper cites the one you are viewing
“…Although modern CT-based planning techniques have reduced unnecessary cardiac exposure, studies with over 10 years of follow-up are still needed to assess the true incidence of late cardiac events [1]. Darby et al reported that each 1 Gy increase in mean heart dose is associated with a 7.4% increase in the rate of major coronary events, including myocardial infarction and cardiac death [6,12]. Similarly, Sardaro et al estimated a 4% increase in the risk of late cardiac disease per 1 Gy [6].…”
Section: Discussion
mentioning
confidence: 99%
“…Darby et al reported that each 1 Gy increase in mean heart dose is associated with a 7.4% increase in the rate of major coronary events, including myocardial infarction and cardiac death [6,12]. Similarly, Sardaro et al estimated a 4% increase in the risk of late cardiac disease per 1 Gy [6].…”
Section: Discussion
mentioning
confidence: 99%