2014
DOI: 10.1039/c4tb00169a
|View full text |Cite
|
Sign up to set email alerts
|

Dopamine amperometric detection at a ferrocene clicked PEDOT:PSS coated electrode

Abstract: An amperometric sensor based on an ITO electrode coated with ferrocene clicked PEDOT:PSS is described and the electrocatalytical performance of the device towards dopamine is assessed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(40 citation statements)
references
References 43 publications
(44 reference statements)
0
36
0
Order By: Relevance
“…Attaching a moiety such as this to the polymer films, and showing that the modified material responds dramatically to the electrical activity of the environment, would show the potential of similar chemistries for making chemical sensors based on these materials. 40 The electrochemical behavior of the resulting polymer films was investigated by CV. The comparison of the CV curves of the pristine and modified films is shown in Fig.…”
Section: Post-polymerization Functionalization and Electrochemical Chmentioning
confidence: 99%
“…Attaching a moiety such as this to the polymer films, and showing that the modified material responds dramatically to the electrical activity of the environment, would show the potential of similar chemistries for making chemical sensors based on these materials. 40 The electrochemical behavior of the resulting polymer films was investigated by CV. The comparison of the CV curves of the pristine and modified films is shown in Fig.…”
Section: Post-polymerization Functionalization and Electrochemical Chmentioning
confidence: 99%
“…Scavetta et al prepared a CME by coating ITO electrodes with a ferrocene-functionalized poly(3,4-ethylenedioxythiophene):poly(styrene-4-sulfonate) (PEDOT:PSS) film [110]. The two-step procedure implied the electrodeposition of azidomethyl functionalized 3,4-ethylenedioxythiophene (PEDOT-N3) followed by copper-catalyzed azide-alkyne cycloaddition of ethynylferrocene.…”
Section: Botelho Do Rego Et Al Performed a Cv/xps Investigation Of Tmentioning
confidence: 99%
“…They decorated the indium-tin-oxide (ITO) electrodes through electrodeposition of PEDOT-N 3 followed by CuAAC with 2. Afterwards, the Fc-decorated electrode could be used as an amperometric sensor for the detection of dopamine with an average sensitivity of 196 mA M -1 cm -2 , and a limit of detection of 1 lM [44].…”
Section: Click Modification Of General Polymersmentioning
confidence: 99%