2009
DOI: 10.1117/12.808990
|View full text |Cite
|
Sign up to set email alerts
|

DMD diffraction measurements to support design of projectors for test and evaluation of multispectral and hyperspectral imaging sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
21
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(23 citation statements)
references
References 10 publications
0
21
0
Order By: Relevance
“…The angle of incidence of the collimated beam on the DMD has to be the "blaze" angle, so that diffraction from the micromirror array is minimised [29]. The blaze angle is wavelength dependent and within a very small range, so careful alignment is necessary to achieve it.…”
Section: B Measurement System Layoutmentioning
confidence: 99%
“…The angle of incidence of the collimated beam on the DMD has to be the "blaze" angle, so that diffraction from the micromirror array is minimised [29]. The blaze angle is wavelength dependent and within a very small range, so careful alignment is necessary to achieve it.…”
Section: B Measurement System Layoutmentioning
confidence: 99%
“…The slight angular disparity of the text with respect to the stage movement axes is believed to be a slight misalignment of the vertical axis of the DMD surface. On the assumption that 1000 structures with width of 30µm can be fabricated in 1 second (based on the 1kHz laser repetition rate), a coverage of 1mm 2 could, in theory, be fabricated within a timescale of order seconds. However, in practice, it is likely that the stage movement would not be accurate enough when operating at this required speed.…”
Section: Contiguous Structuresmentioning
confidence: 99%
“…For micron-scale fabrication, laser machining via DMDs is proposed as an alternative approach to existing focused-ion-beam and electron-beam lithography-based techniques which, although offering significantly higher resolutions, are both based on serial processing, and hence are intrinsically much slower fabrication tools. Due to their low-cost and high switching speeds, DMDs are rapidly becoming an attractive approach for applications in the photonics and medical sciences [2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…OPO sources aand quantum cascade laser sources do not have the spectral coverage. To meet testing requirements for IR sensor systems, we have developed a broadband fiber based supercontinuum mid-IR source for projection systems..The National Institute of Standards and Technology (NIST), Gaithersburg, MD, is developing a Hyperspectral Image Projector (HIP) for the testing, calibration, and system-level validation of multispectral and hyperspectral imaging sensors [1,2]. The system is capable of projecting scenes with specific spectral content at video frame rates.…”
mentioning
confidence: 99%
“…The National Institute of Standards and Technology (NIST), Gaithersburg, MD, is developing a Hyperspectral Image Projector (HIP) for the testing, calibration, and system-level validation of multispectral and hyperspectral imaging sensors [1,2]. The system is capable of projecting scenes with specific spectral content at video frame rates.…”
mentioning
confidence: 99%