2014
DOI: 10.1002/jcla.21818
|View full text |Cite
|
Sign up to set email alerts
|

Discovery and Correction of Spurious Low Platelet Counts due to EDTA‐Dependent Pseudothrombocytopenia

Abstract: The method of screening for platelet clumping with the help of XE5000 images is convenient. The decline in the platelet count is related to the length of time and the intensity of chelation. Amikacin supplement is not always effective for correcting platelet counts in vitro.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
2
5

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(39 citation statements)
references
References 39 publications
(54 reference statements)
0
32
2
5
Order By: Relevance
“…On the other hand, platelet clumps and giant platelets owing to their large size are not counted as platelets in automated analyzers. All these lead to inaccurate platelet counts in an automated hematology analyzer [8][9][10][11] . Hence platelet count values obtained from automated analyzers should be crosschecked by some other method particularly in cases of thrombocytopenia [12] .…”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, platelet clumps and giant platelets owing to their large size are not counted as platelets in automated analyzers. All these lead to inaccurate platelet counts in an automated hematology analyzer [8][9][10][11] . Hence platelet count values obtained from automated analyzers should be crosschecked by some other method particularly in cases of thrombocytopenia [12] .…”
Section: Discussionmentioning
confidence: 99%
“…However, the scattergram displayed from the immature myeloid information (IMI) channel in XE-2100 improved platelet aggregates detection. Therefore, screening for platelet clumps in XE-2100 by using platelet clump flag along with the images provided by the IMI channel is convenient [11]. Sensitivity and specificity for platelet clumps detection may vary according to the flag threshold selected by the user, which was the reason why our results highlighted the point that each laboratory should determine specific threshold flags according to their population.…”
mentioning
confidence: 69%
“…Some of these anticoagulants need to be prepared extemporaneously. Another possibility is the addition of calcium chloride [44], anti-platelet drugs (acetylsalicylic acid, prostaglandin E 1 , apyrase, monoclonal antibodies directed against GpIIb/IIIa), potassium azide, kanamycin, amikacin, or other aminosides [54][55][56], which prevent the formation of clumps or dissociate them.…”
Section: Alternatives To Edtamentioning
confidence: 99%