2021
DOI: 10.15605/jafes.036.02.02
|View full text |Cite
|
Sign up to set email alerts
|

Discordance between Fasting Plasma Glucose (FPG) and HbA1c in Diagnosing Diabetes and Pre-diabetes in The Malaysian Cohort

Abstract: Objective. In this present study, we aim to evaluate the accuracy of the HbA1c relative to fasting plasma glucose (FPG) in the diagnosis of diabetes and pre-diabetes among The Malaysian Cohort (TMC) participants.Methodology. FPG and HbA1c were taken from 40,667 eligible TMC participants that have no previous history of diabetes, aged between 35-70 years and were recruited from 2006 -2012. Participants were classified as normal, diabetes and pre-diabetes based on the 2006 World Health Organization (WHO) criteri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 21 publications
0
12
1
Order By: Relevance
“… 34 Previous studies have shown a significant discordance in the diagnosis of diabetes between HbA1c and fasting blood glucose. 35 , 36 Second, valid genetic instruments for HbA1c levels ( n = 213) are as much as 10 times higher than fasting glucose levels ( n = 22). These findings suggest that, in clinical practice, a strict glycemic control strategy that encompasses regular exercise and a healthy diet is necessary to reduce the risk of myopia.…”
Section: Discussionmentioning
confidence: 99%
“… 34 Previous studies have shown a significant discordance in the diagnosis of diabetes between HbA1c and fasting blood glucose. 35 , 36 Second, valid genetic instruments for HbA1c levels ( n = 213) are as much as 10 times higher than fasting glucose levels ( n = 22). These findings suggest that, in clinical practice, a strict glycemic control strategy that encompasses regular exercise and a healthy diet is necessary to reduce the risk of myopia.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, all instruments used in this study were certified by the National Glycohemoglobin Standardization Program (NGSP) and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) in 2020 and 2021, as well as standardized to the method used by the Diabetes Control and Complications Trial (DCCT). All assays were performed according to the manufacturer's instructions in an accredited bioanalytical laboratory 7 …”
Section: Methodsmentioning
confidence: 99%
“…As for the original protocol for samples in 2012 and 2013, fresh whole blood samples from EDTA tubes were measured for HbA1c using Premier Hb9210 HbA1c analyzer (Trinity Biotech, WW, Ireland) that utilizes boronate affinity technology for high-performance liquid chromatography (HPLC). 7 The quoted machine's reportable values range between 4% and 18% HbA1c. 19 For this current study (in 2020 and 2021), we retrieved the whole blood samples from the same participants we measured in 2012 and 2013 stored at −196°C in a liquid nitrogen tank at TMC's biobank.…”
Section: Hba1c Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…To date, the gold standard test for prediabetes diagnosis is the oral glucose tolerance test (OGTT), fasting plasma glucose (FPG), and HbA 1c levels (11,12). However, several studies have shown discordance between HbA 1c and glycemia (17)(18)(19)(20)(21). This discordance could have a significant impact on clinical practice.…”
Section: Introductionmentioning
confidence: 99%