1998
DOI: 10.1016/s0378-4347(98)00353-3
|View full text |Cite
|
Sign up to set email alerts
|

Direct plasma injection for high-performance liquid chromatographic–mass spectrometric quantitation of the anxiolytic agent CP-93 393

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0

Year Published

1999
1999
2008
2008

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(32 citation statements)
references
References 15 publications
0
32
0
Order By: Relevance
“…Consequently, there is considerable interest in developing an on-line sample preparation procedure to overcome the need for the time-consuming evaporation and reconstitution steps that are used in typical off-line sample preparation methods. On-line direct analyses of biological fluids have been reported, using a column switching technique with a restricted access colum 31 or solid-phase extraction cartridge. 32 Thus, the focus of the present work was to compare APCI LC/MS with APPI LC/MS in terms of detection sensitivity and matrix effects, to optimize the experimental factors that affect the performance of the competing API techniques, and to develop a column switching technique as a on-line sample preparation method for patulin in apple juice.…”
mentioning
confidence: 99%
“…Consequently, there is considerable interest in developing an on-line sample preparation procedure to overcome the need for the time-consuming evaporation and reconstitution steps that are used in typical off-line sample preparation methods. On-line direct analyses of biological fluids have been reported, using a column switching technique with a restricted access colum 31 or solid-phase extraction cartridge. 32 Thus, the focus of the present work was to compare APCI LC/MS with APPI LC/MS in terms of detection sensitivity and matrix effects, to optimize the experimental factors that affect the performance of the competing API techniques, and to develop a column switching technique as a on-line sample preparation method for patulin in apple juice.…”
mentioning
confidence: 99%
“…However, such approaches did not work adequately for the recovery of the penicillins from the matrix containing Micafungin (poor recovery rate up to 40%, data not shown), and careful attention was required to handle a trace amount of the penicillins during the extraction procedure. To improve the accuracy of the method without extraordinary handling, an on-line extraction was examined using the column switching technique, [11][12][13][14] which enables reduction of the loss of analytes during the extraction procedure. Figure 3 shows diagrams of an HPLC equipped with a valve for the column switching technique.…”
Section: Resultsmentioning
confidence: 99%
“…As little as 0.5 ng/mL of these compounds could be quantified by this method. An anxiolytic under clinical evaluation (CP-93 393) was also analyzed by online extraction from plasma by a RAM column (Needham et al, 1998) packed with porous silica coated with a1-acid glycoprotein with C 18 internal surface (Bio Trap 500 column). Recently, Fitzgerald et al (1999) developed a broad-spectrum LC/LC/LC-MS/MS to determine 17 basic drugs from different class (opiates, amphetamines, benzodiazepines, etc.)…”
Section: Hplc-msmentioning
confidence: 99%