2016
DOI: 10.1002/adbi.201600003
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Diamond Devices for High Acuity Prosthetic Vision

Abstract: Retinal implants restore a sense of vision, for a growing number of users worldwide. Nevertheless, visual acuities provided by the current generation of devices are low. The quantity of information transferable to the retina using existing implant technologies is limited, far below receptor cells' capabilities. Many agree that increasing the information density deliverable by a retinal prosthesis requires devices with stimulation electrodes that are both dense and numerous. This work describes a new generation… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
47
11
3
0

Citation Types

0
62
0
0

Year Published

2014
2014
2026
2026

Publication Types

Select...
43
6
5
2

Relationship

17
39

Authors

Journals

citations

Cited by 56 publications

(62 citation statements)
references

References 51 publications

0
62
0
0
Order By: Relevance
How this paper cites the one you are viewing
“…The system produces stimulation pulses in line with earlier reports [22] . The implant is packaged using diamond packaging technology for safe and effective neuromodulation, aspects of which has been reported in our earlier works [22] .…”
Section: Discussion
mentioning
confidence: 59%
“…The interface circuit demodulated the optically encoded data and produced signals with rise/fall times of 112/160 nm for the stimulator ASIC operation. The system produces stimulation pulses in line with earlier reports [22] . The implant is packaged using diamond packaging technology for safe and effective neuromodulation, aspects of which has been reported in our earlier works [22] .…”
Section: Discussion
mentioning
confidence: 59%
“…[22] Further information on the silicone housing as well as the surgical placement has been provided in our earlier work. [22,39] Beyond some minor changes to the form factor, the key difference between these earlier reports and this work is that the silicone housing no longer contains the electrical wires. These wires represented a significant surgical challenge because they needed to breach the eyewall, and in this work we successfully eliminated the need for them.…”
Section: Discussion
mentioning
confidence: 99%
See 2 more Smart Citations
How this paper cites the one you are viewing
“…The system produces stimulation pulses in line with earlier reports [22] . The implant is packaged using diamond packaging technology for safe and effective neuromodulation, aspects of which has been reported in our earlier works [22] .…”
Section: Discussion
mentioning
confidence: 59%
“…The interface circuit demodulated the optically encoded data and produced signals with rise/fall times of 112/160 nm for the stimulator ASIC operation. The system produces stimulation pulses in line with earlier reports [22] . The implant is packaged using diamond packaging technology for safe and effective neuromodulation, aspects of which has been reported in our earlier works [22] .…”
Section: Discussion
mentioning
confidence: 59%
“…[22] Further information on the silicone housing as well as the surgical placement has been provided in our earlier work. [22,39] Beyond some minor changes to the form factor, the key difference between these earlier reports and this work is that the silicone housing no longer contains the electrical wires. These wires represented a significant surgical challenge because they needed to breach the eyewall, and in this work we successfully eliminated the need for them.…”
Section: Discussion
mentioning
confidence: 99%
See 1 more Smart Citation
How this paper cites the one you are viewing
“…32 The safety of N-UNCD for chronic applications has been previously demonstrated by implanting N-UNCD adjacent to the retina tissue. 36 As such, a potential application of our findings could involve the use of N-UNCD electrodes in retinal implants, alongside NIR stimulation, to slow down or rescue the degeneration of neurons in retinal diseases such as retinitis pigmentosa and age-related macular degeneration.…”
Section: Limitations
mentioning
confidence: 85%
How this paper cites the one you are viewing
“…From the engineering point of view this implies to increase the density of the stimulating electrodes and enlarge the size of the prosthesis. POLYRETINA is a novel foldable and photovoltaic wide-field epiretinal prosthesis with a remarkable increase in its size (46.3 degrees) and in the number of stimulating pixels (2215) compared to other epiretinal prostheses 4 , 34 .…”
Section: Discussion
mentioning
confidence: 99%