2023
DOI: 10.1002/mp.16757
|View full text |Cite
|
Sign up to set email alerts
|

Diamond detectors for dose and instantaneous dose‐rate measurements for ultra‐high dose‐rate scanned helium ion beams

Thomas Tessonnier,
Gianluca Verona‐Rinati,
Luisa Rank
et al.

Abstract: BackgroundThe possible emergence of the FLASH effect—the sparing of normal tissue while maintaining tumor control—after irradiations at dose‐rates exceeding several tens of Gy per second, has recently spurred a surge of studies attempting to characterize and rationalize the phenomenon. Investigating and reporting the dose and instantaneous dose‐rate of ultra‐high dose‐rate (UHDR) particle radiotherapy beams is crucial for understanding and assessing the FLASH effect, towards pre‐clinical application and qualit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 51 publications
(109 reference statements)
0
3
0
Order By: Relevance
“…The delivery and measurement of dose and dose rate was performed at HIT, following experimental procedure for instantaneous dose rate acquisition. 24 For each investigated plan, the delivery time structure of the irradiated spill was recorded by the beam monitor chamber with a 50 µs time resolution for a helium ion beam irradiation with an energy of 145. (range in water of approximatively 14.6 cm).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The delivery and measurement of dose and dose rate was performed at HIT, following experimental procedure for instantaneous dose rate acquisition. 24 For each investigated plan, the delivery time structure of the irradiated spill was recorded by the beam monitor chamber with a 50 µs time resolution for a helium ion beam irradiation with an energy of 145. (range in water of approximatively 14.6 cm).…”
Section: Methodsmentioning
confidence: 99%
“…Dose rate measurements were performed with diamond prototype detectors (sensitive volume 1.1 mm in diameter, 1 µm thick, PTW) coupled with a transconductance amplifier (DLPCA200-FEMTO) and a digital oscilloscope. 24,25 To investigate the performance of the dose rate engine in-depth along the beam, a 2 cm × 2 cm field with a 2 mm spot separation in x and y, resulting in 121 individual spots was used. The number of particles was set to 2.2 × 10 9 , close to the maximum number of particles deliverable in one spill with helium ions at HIT at the time of the study.…”
Section: Methodsmentioning
confidence: 99%
“…By using a transimpedance amplifier and a digital oscilloscope, a temporal resolution in the range of a few ns could be achieved (Marinelli et al 2023). Additionally, the temporal structure of scanned pencil beams can also be detected (Tessonnier et al 2023).…”
Section: Flash Diamondmentioning
confidence: 99%