Abstract: The Stator winding insulation is aged by exposure to a combination of thermal, electrical, mechanical, and environmental stresses. Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of large generator. In the paper, two new parameters are proposed for the diagnosis of stator winding insulation based on the test results of multistress accelerating aging test of stator bars. The test results show that the skewness of partial discharge ph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 12 publications
0
11
0
Order By: Relevance
“…The shapes of max ( ), ( ), ( ), and three-dimensional distribution ( , ) changed with aging time. These distributions have characteristic shapes, which vary with the type of the defects [19]. Experience has shown that the shape belonging to the positive half of the HV sine wave differs much from that of the negative half, so that their characteristic shapes are available for recognition purposes.…”
Section: Phase Resolved Pd Analysismentioning
confidence: 99%
“…The shapes of max ( ), ( ), ( ), and three-dimensional distribution ( , ) changed with aging time. These distributions have characteristic shapes, which vary with the type of the defects [19]. Experience has shown that the shape belonging to the positive half of the HV sine wave differs much from that of the negative half, so that their characteristic shapes are available for recognition purposes.…”
Section: Phase Resolved Pd Analysismentioning
confidence: 99%
“…Stone et al [17] reviewed the mechanisms of slot discharge and vibration sparking, and the methods to detect and repair them. Yue et al proposed two health measure of the skewness of PD phase resolved distribution and the high-frequency crest of PD impulse based upon a multistress accelerating aging test of stator windings [18]. Fernando et al found that the frequency-domain spectroscopy and estimated parameters are informative to assess the generator insulation condition with a laboratory generator bar experiment [19].…”
Section: Introductionmentioning
confidence: 99%
“…Compared to other methods for insulation defect diagnosis, PDD has several advantages, including more sensitive, non-destructive & non intrusive, and able to be performed on-site or even online [16]. As a result, PDD has been popularly used for monitoring insulation systems, especially high voltage insulation systems, such as generators [30], transformers [2] [3], and HV cables [19]. Since PD signals are generally low signal-to-noise ratio in nature, feature extraction and effective feature dimensionality reduction are even more important in the design of PDD systems.…”
Section: Introductionmentioning
confidence: 99%