2013
DOI: 10.1016/j.talanta.2012.10.042
|View full text |Cite
|
Sign up to set email alerts
|

Development of optical immunosensors for detection of proteins in serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
10
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 31 publications
0
10
0
Order By: Relevance
“…After conditioning, the SPR chamber was supplemented with 100 μL of buffer and conditioned for 30 min. GST-His 6 -JAK2 probe was diluted with buffer to 1x10 -6 M, briefly vortexed and injected on a modified SPR gold disc (6,12,26, and 44 L) in order to obtain the following concentrations: 50, 100, 200, 300 nM. After 2h incubation, GST-His 6 -JAK2 solution was rinsed off with 2 mL of the buffer and the value of the SPR angle shift was recorded 20 min after the end wash.…”
Section: Immobilization Of Gst-his 6 -Jak2mentioning
confidence: 99%
See 1 more Smart Citation
“…After conditioning, the SPR chamber was supplemented with 100 μL of buffer and conditioned for 30 min. GST-His 6 -JAK2 probe was diluted with buffer to 1x10 -6 M, briefly vortexed and injected on a modified SPR gold disc (6,12,26, and 44 L) in order to obtain the following concentrations: 50, 100, 200, 300 nM. After 2h incubation, GST-His 6 -JAK2 solution was rinsed off with 2 mL of the buffer and the value of the SPR angle shift was recorded 20 min after the end wash.…”
Section: Immobilization Of Gst-his 6 -Jak2mentioning
confidence: 99%
“…Here, we present the work on biosensors based on the principle of surface plasmon resonance (SPR), which have emerged among the most widely used label free detection tools for the study of biomolecular interactions such as protein-protein [9,10], antibody-antigen [11,12] and receptor-ligand [13,14]. SPR offers the ability for direct measuring of interactions in real time, which allows the quantitative determination of kinetic and thermodynamic parameters [15].…”
Section: Introductionmentioning
confidence: 99%
“…Although current PC biosensor methodologies require a laboratory setting, a portable optical interface capable of converting a smartphone into a detection instrument was recently designed for the PC biosensor (Gallegos et al, 2013). Nevertheless, the most significant challenge continues to be the accurate and sensitive detection of biomarkers in complex matrixes (Marks, 2002;Kyprianou et al, 2013).…”
Section: Introductionmentioning
confidence: 99%
“…serum and whole blood) containing variable amounts of interfering proteins are the primary cause of non-specific binding and poor signal-to-noise responses (Kyprianou et al, 2013), which results in unreliable data. These can lead to false-negative or false-positive clinical results that instead increase healthcare costs and burden the health of patients.…”
Section: Introductionmentioning
confidence: 99%
“…SPR and SPRi immunosensors are particularly interesting to detect biomolecular interactions in real time with complex biological media [7][8][9]. This is due to their ability to detect biomolecular interactions in a label-free manner [10] and to their high sensitivity and "real-time monitoring" capabilities [11].…”
mentioning
confidence: 99%