Abstract: We report the design and analysis of a novel compensation chamber for use in PHUMP, a multiple condenser loop heat pipe (LHP) capable of dissipating 1000 W. The LHP is designed for integration into a high performance air-cooled heat sink to address thermal management challenges in advanced electronic systems. The compensation chamber is integrated into the evaporator of the device and provides a region for volumetric expansion of the working fluid over a range of operating temperatures. Additionally, the compe… Show more