2018
DOI: 10.1016/j.aca.2018.05.016
| |Summarize |Cite
|
Sign up to set email alerts

Development and validation of a multidimensional gas chromatography/combustion/isotope ratio mass spectrometry-based test method for analyzing urinary steroids in doping controls

Search citation statements

Order By: Relevance

Paper Sections

Select...
19
5
2
1

Citation Types

2
30
0
0

Year Published

Range
2018
2018
2026
2026

Publication Types

Select...
20
2

Relationship

4
18

Authors

Journals

Cited by 22 publications

(32 citation statements)

References 38 publications

2
30
0
0
Order By: Relevance
How the paper below cites the one you are viewing
“…One conclusion of this study was that epiandrosterone sulfate served as a suitable marker for testosterone administration over a longer period than other reported markers suggesting that this method of analysis facilitated by PaS variants could improve the detection capabilities of antidoping laboratories. Concordant with the results of this study, the PVFV-PaS variant, with greater thermostability and activity for EAS hydrolysis (Figures and ), provided higher yields of free steroid during sample preparation than WT-PaS, highlighting the real world benefits of this mutagenesis study. , …”
Section: Discussion
supporting
confidence: 85%
“…In this complementary study, PVFV-PaS-mediated sample preparation enabled measurements of epiandrosterone liberated from epiandrosterone sulfate, a metabolite of testosterone and related androgenic anabolic steroids. 12,13 The GC-CIR-MS technique provides an avenue to distinguish between endogenous steroid metabolites and those derived from otherwise identical exogenously administered steroids of synthetic origin. One conclusion of this study was that epiandrosterone sulfate served as a suitable marker for testosterone administration over a longer period than other reported markers suggesting that this method of analysis facilitated by PaS variants could improve the detection capabilities of anti-doping laboratories.…”
Section: Discussion
mentioning
confidence: 99%
“…Concordant with the results of this study, the PVFV-PaS variant, with greater thermostability and activity for EAS hydrolysis ( Figures 5 and 6), provided higher yields of free steroid during sample preparation than WT-PaS, highlighting the real world benefits of this mutagenesis study. 11,13…”
Section: Discussion
mentioning
confidence: 99%
“…Simultaneous to the development of this manuscript, two reports , of work conducted within the World Anti-Doping Agency-accredited laboratory based at the Institute of Biochemistry, German Sport University, Cologne employed the PVFV-PaS mutant, described for the first time in this work, for sample preparation prior to Gas Chromatography-Carbon Isotope Ratio-Mass Spectrometry (GC–CIR-MS). In this complementary study, PVFV-PaS-mediated sample preparation enabled measurements of epiandrosterone liberated from epiandrosterone sulfate, a metabolite of testosterone and related androgenic anabolic steroids. , The GC–CIR-MS technique provides an avenue to distinguish between endogenous steroid metabolites and those derived from otherwise identical exogenously administered steroids of synthetic origin.…”
Section: Discussion
mentioning
confidence: 99%
See 3 more Smart Citations