2015
DOI: 10.1016/j.enbuild.2014.11.031
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a three dimensional thermal transient numerical model with sun patch: Application to a low energy cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…The HSR cabin ventilation model has been validated in the author’s previous publication. 17 Here, the radiation model was validated using Rodler’s experimental data 21 and Gendelis’s simulation results. 22…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The HSR cabin ventilation model has been validated in the author’s previous publication. 17 Here, the radiation model was validated using Rodler’s experimental data 21 and Gendelis’s simulation results. 22…”
Section: Resultsmentioning
confidence: 99%
“…The HSR cabin ventilation model has been validated in the author's previous publication. 17 Here, the radiation model was validated using Rodler's experimental data 21 and Gendelis's simulation results. 22 Rodler's experiment was carried out in a thermal test building at the BESTLab (Building Envelop and Solar Technology Laboratory), which is located in 48 22 0 N 249 0 E. The model represents a single room with 2.97 m in depth, 2.89 m in width and 2.82 m in height.…”
Section: Validation Of Numerical Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…Numerous studies concerning the combination of a passive solar building design along with a FHS have been conducted. For instance, Rodler et al (2014) validated a numerical model capable of reproducing the footprint of a sun patch on the floor and walls through an experimental work conducted at the French EDF BESTLab. The study showed that a convenient use of stored solar energy in the walls and floor enhances the overall building energy performances.…”
Section: Introductionmentioning
confidence: 99%
“…Depending on the positions of the window and the sun, there are 20 cases of figures and each of them has an explicit and distinct equation. Authors in [14][15][16][17][18][19][20] modelled and counted the SSA for a cell oriented to the west and located in Paris. The localization is verified by the application of a membership test whose principle is to verify the inclusion or not of the projections of the centers of the meshes on a plane perpendicular to the rays of the sun in the polygon resulting from the projection of the window on the same plan.…”
Section: Introductionmentioning
confidence: 99%