2019
DOI: 10.1109/access.2019.2960338
|View full text |Cite
|
Sign up to set email alerts
|

Development and Testing of a Prototype for 3D Radial Pulse Image Measurement and Compatible With 1D Pulse Wave Analysis

Abstract: This study proposes the prototype of a wrist pulse acquisition device with three-dimensional pulse image (3DPI) obtained at the radial artery. The proposed prototype is designed with mechanical and electronic circuit hardware as well as the control and data acquisition software to have fourteen degrees of movement freedom against the sophisticated geometry of the wrist radial artery for accurate pulse-taking. Three robot fingers with nine degrees of movement freedom and a wrist fixer with two degrees of rotati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 29 publications
0
14
0
Order By: Relevance
“…These three types of tactile sensors cover the most typical categories of available commercial PPS tactile sensors. To demonstrate the broad applicability of our approach, the tactile sensors in this study differ in terms of model, parameters, production years [ [8] , [9] , [10] ] and used times. Each experiment utilizes a specific PPS tactile sensor mounted on the robot finger and maintains a specific depth of the robot finger for a measurement pressure consistent with that of SphygmoCor close by the robot finger.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…These three types of tactile sensors cover the most typical categories of available commercial PPS tactile sensors. To demonstrate the broad applicability of our approach, the tactile sensors in this study differ in terms of model, parameters, production years [ [8] , [9] , [10] ] and used times. Each experiment utilizes a specific PPS tactile sensor mounted on the robot finger and maintains a specific depth of the robot finger for a measurement pressure consistent with that of SphygmoCor close by the robot finger.…”
Section: Methodsmentioning
confidence: 99%
“…3 Illustration of 3DPIs employed in this study. (a) the superimposed stereoscopic 3DPIs of 24 subjects (12- channel [ 8 ]); (b) the stereoscopic display of a simulated 3DPI (60 × 60 matrix). The x-axis and the y-axis of a 3D coordinate system define the pulse length along the direction of arterial blood flow while the pulse width corresponds to the pulse width perpendicular to that direction.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations