2020
DOI: 10.3389/fphys.2020.552942
|View full text |Cite
|
Sign up to set email alerts
|

Development and Clinical Application of a Novel Non-contact Early Airflow Limitation Screening System Using an Infrared Time-of-Flight Depth Image Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(16 citation statements)
references
References 18 publications
0
11
0
Order By: Relevance
“…However, it is not our aim to perform the automatic detection of IFL. This should be left to the current automated IFL detection system [42]- [45]. Although the annotation for IFL was not provided with proper physiological reasoning (i.e., the S1→S2→S3 transition represents the progressive closure of the UA) and high sensitivity and specificity, our proposition that the region between the alpha and theta thresholds may represent a considerable reduction in the flow can be validated concomitantly.…”
Section: F Significance Of Ordmentioning
confidence: 98%
“…However, it is not our aim to perform the automatic detection of IFL. This should be left to the current automated IFL detection system [42]- [45]. Although the annotation for IFL was not provided with proper physiological reasoning (i.e., the S1→S2→S3 transition represents the progressive closure of the UA) and high sensitivity and specificity, our proposition that the region between the alpha and theta thresholds may represent a considerable reduction in the flow can be validated concomitantly.…”
Section: F Significance Of Ordmentioning
confidence: 98%
“…Moreover, research [ 69 ] states that the RR can be used as one of the most efficient indicators to determine whether a person is healthy. Anomalous RR is critical for detecting significant health problems and can also be used to forecast potentially serious clinical outcomes such as influenza classification [ 42 ], lung airflow limitation [ 70 ], and sleep apnea screening. Additionally, monitoring variations in RR can assist in identifying a high-risk intensive care patient up to 24-h before a medical emergency.…”
Section: Thermal Camera For Physiological Measurementmentioning
confidence: 99%
“…Therefore, they demand for the quiet environment, and have a poor performance on measuring FVC [11,12] because the second half of the test is mostly inaudible to microphone. In recent years, time-of-flight (ToF) sensors have also been utilised to develop non-contact devices for PFT [16,17]. The authors in ref.…”
Section: Introductionmentioning
confidence: 99%
“…The authors in ref. [17] used an infrared ToF depth image sensor to model anterior-thorax three-dimensional motions, and conducted the multiple linear regression analysis to estimate the actual FVC from the ToF-derived FVC and somatotype data. The optical signal emitted by the ToF sensors has poor penetration of clothing.…”
Section: Introductionmentioning
confidence: 99%