Determining the emissivity of pig skin for accurate infrared thermography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
54
2
3

Year Published

2015
2015
2021
2021

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 84 publications
(67 citation statements)
references
References 25 publications
3
54
2
3
Order By: Relevance
“…An infrared camera (Mikron M7500; Hancock, MI) was positioned above the sample and additional thermocouples (Model IT-18; Physitemp ;Clifton, NJ) were placed on the tissue surface approximately 5 cm from antenna (outside heated zone) to calibrate temperature values derived from the IR camera. We assumed tissue emissivity of 0.9 [27]. The tissue surface temperature was recorded via IR camera (~3.3 fps, 320×240 resolution) for the duration of the experiment and the image sequence was stored for later image analysis.…”
Section: Methodsmentioning
confidence: 99%
“…An infrared camera (Mikron M7500; Hancock, MI) was positioned above the sample and additional thermocouples (Model IT-18; Physitemp ;Clifton, NJ) were placed on the tissue surface approximately 5 cm from antenna (outside heated zone) to calibrate temperature values derived from the IR camera. We assumed tissue emissivity of 0.9 [27]. The tissue surface temperature was recorded via IR camera (~3.3 fps, 320×240 resolution) for the duration of the experiment and the image sequence was stored for later image analysis.…”
Section: Methodsmentioning
confidence: 99%
“…Animals were manually held and filmed at a constant distance (0.35 m). The animal emissivity was set to 0.98 and the tumor borders were marked to overlap with a visible image [29]. Representative frames were selected and analyzed using the ThermaCam Researcher Pro 2.10 (FLIR Systems, Inc., USA) software.…”
Section: Thermographic Evaluationmentioning
confidence: 99%
“…The emissivity of the object used (fresh pork meat and liver bought from a supermarket) is set to be 0.97. The human skin exhibits an emissivity 0.97, 17 and is very close with the emissivity values of the pork meat 18 and liver. 19 The distance parameter is required to compensate for the fact that radiation could be absorbed and lost during its transmission into camera lens.…”
Section: Parameters Setting For Infrared Cameramentioning
confidence: 61%