2001
DOI: 10.1021/jf000660n
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Bisphenol A in Food-Simulating Liquids Using LCED with a Chemically Modified Electrode

Abstract: Liquid chromatography with electrochemical detector (LC-ED), using a chemically modified electrode coated with a metalloporphyrin film, is reported for determination of bisphenol A (BPA) migration from polycarbonate baby bottles. The extraction process of the samples was performed according to regulations of the Southern Common Market (MERCOSUR), where certain food-simulating liquids [(A) distilled water, (B) acetic acid 3% V/V in distilled water, and (C) ethanol 15% V/V in distilled water] are defined along w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
20
0
1

Year Published

2002
2002
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 57 publications
(22 citation statements)
references
References 12 publications
0
20
0
1
Order By: Relevance
“…BPA Analysis ---Unheated and heated samples were opened and the 180-ml water samples were taken, from more than one can if necessary, for analysis. To these samples, 1 µg of BPA-d 16 (Kanto Chemical Co., INC., Tokyo, Japan) was added as an internal standard. The samples were passed through a solid-phase extraction cartridge (Sep-Pak plus PS-2, Waters Ltd., U.S.A.), which was cleaned with solvents in advanced, at a rate of 5 ml/min using an automatic pump (Concentrator, Waters Co., U.S.A.).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…BPA Analysis ---Unheated and heated samples were opened and the 180-ml water samples were taken, from more than one can if necessary, for analysis. To these samples, 1 µg of BPA-d 16 (Kanto Chemical Co., INC., Tokyo, Japan) was added as an internal standard. The samples were passed through a solid-phase extraction cartridge (Sep-Pak plus PS-2, Waters Ltd., U.S.A.), which was cleaned with solvents in advanced, at a rate of 5 ml/min using an automatic pump (Concentrator, Waters Co., U.S.A.).…”
Section: Methodsmentioning
confidence: 99%
“…After extraction, the cartridge was centrifuged to remove water remaining therein. BPA and BPA-d 16 in the cartridge were eluted with 9 ml of dichloromethane at 1 ml/min. At the same time, a *To whom correspondence should be addressed: Faculty of Environmental Studies, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations