2013
DOI: 10.1016/j.talanta.2012.11.027
|View full text |Cite
|
Sign up to set email alerts
|

Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
23
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 43 publications
1
23
0
Order By: Relevance
“…This confirms earlier studies with a different cell in which the capacitances were experimentally determined differently, namely from Bode plots (plots of signal vs. frequency) . Shen and co‐workers also studied in detail the effect of solution conductivity on wall capacitance and found a clear correlation, that is, the wall capacitance was higher for solutions of higher conductivity . The authors proposed a model for a likely explanation, namely that the field lines between the electrodes are following different paths for materials of different conductivity inside the tubing.…”
Section: Fundamental Aspectssupporting
confidence: 75%
See 1 more Smart Citation
“…This confirms earlier studies with a different cell in which the capacitances were experimentally determined differently, namely from Bode plots (plots of signal vs. frequency) . Shen and co‐workers also studied in detail the effect of solution conductivity on wall capacitance and found a clear correlation, that is, the wall capacitance was higher for solutions of higher conductivity . The authors proposed a model for a likely explanation, namely that the field lines between the electrodes are following different paths for materials of different conductivity inside the tubing.…”
Section: Fundamental Aspectssupporting
confidence: 75%
“…together with a simplified equivalent circuit diagram. Shen and co‐workers carried out fundamental studies of this standard cell configuration with an impedance analyzer, and found that the measured wall capacitances are significantly smaller than the values calculated from the formula for a coaxial capacitor. This confirms earlier studies with a different cell in which the capacitances were experimentally determined differently, namely from Bode plots (plots of signal vs. frequency) .…”
Section: Fundamental Aspectsmentioning
confidence: 93%
“…Shen et al. presented a similar arrangement employing two detector cells for a conventional capillary, but used a very special circuitry which included two resonating quartz crystals 27. The arrangement for conventional capillaries reported herein employs a straightforward standard circuitry and a common cell.…”
Section: Introductionmentioning
confidence: 99%
“…Although disposable electrodes may be a solution, they are costly and inconvenient. 29,30 To date, several studies have been reported to monitor reactions between antigen and antibody in real time without using a labeled compound by an amperometric technique. 24 To overcome these disadvantages, we developed an electrochemical platform which was based on an integrated and contact-free microuidic chip for label-free and real-time impedance monitoring of isothermal nucleic acid amplication directly.…”
Section: Introductionmentioning
confidence: 99%