2018
DOI: 10.1016/j.lfs.2018.05.015
|View full text |Cite
|
Sign up to set email alerts
|

Detection of stress and the effects of central nervous system depressants by gastrointestinal smooth muscle electromyography in wakeful rats

Abstract: The smooth muscle EMG instrument can measure the level of acute stress and is applicable for the investigation of central nervous system affecting drugs through the GI tract in awake rats. This is the first tool to measure the stress response via the GI tract reactions. The technique may open a new perspective in the diagnosis and therapy of psychosomatic disorders.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 27 publications
0
2
0
2
Order By: Relevance
“…"Based on these findings, they concluded that the neurotic personality of athletes could influence their cognitive and physiological responses in a competition" (BALYAN et al, 2016). Szűcs et al (2018) the effects of stress on the central nervous system and gastrointestinal smooth muscle depressants electromyography detected in rats. In the functional gastrointestinal (GI) tract, slow-wave myoelectric signals can be detected by electromyography (EMG).…”
Section: Objective Measurementsmentioning
confidence: 99%
“…"Based on these findings, they concluded that the neurotic personality of athletes could influence their cognitive and physiological responses in a competition" (BALYAN et al, 2016). Szűcs et al (2018) the effects of stress on the central nervous system and gastrointestinal smooth muscle depressants electromyography detected in rats. In the functional gastrointestinal (GI) tract, slow-wave myoelectric signals can be detected by electromyography (EMG).…”
Section: Objective Measurementsmentioning
confidence: 99%
“…The changes in the myoelectric activity of the GIT were followed with SMEMG in parallel with the mechanical contractions in anaesthetised rats using a strain gauge tool. Another SMEMG experiment was carried out in awake rats, measuring GIT activity under normal and stressed conditions [ 19 ].…”
Section: Introductionmentioning
confidence: 99%
“…Magát a módszert illetően, a stressz mérésének műszeres eljárása széles körben elterjedt, de szinte kivétel nélkül csak a szívfrekvencia (HRv, és/vagy EKG) alapján. Az általunk alkalmazott módszer már nemzetközileg is validált, előzetes preklinikai és humán vizsgálatokkal igazolt(SZŰCS et al, 2018) komplex paramétereken nyugszik.Az eredmények feldolgozását általános leíró statisztikával határoztuk meg (MS Excel 2020), illetve végeztünk T-próbát, valamint Mann-Whitney tesztet.…”
unclassified
“…Így lehetséges az is, hogy megfelelő elemszámú és több, különböző tevékenység és inger közben végzett méréssel kimutathatók lesznek az egyes stressz faktorok közötti különbségek".Korábbi kutatások alapján a gyomormotilitásból az elektromos aktivitás gyakoriságát CPM-ben, az aktivitás nagyságát pedig spektrumsűrűségként (PS) jellemezték (K.F Szűcs et. al, 2018)…”
unclassified