2020
DOI: 10.1111/zph.12745
|View full text |Cite
|
Sign up to set email alerts
|

Detection of rabies virus antigen by the indirect rapid immunohistochemistry test in equines and comparisons with other diagnostic techniques

Abstract: Laboratory diagnosis of rabies in equines is essential for distinguishing the disease from other sources of encephalitis. Diagnosis by conventional techniques such as a direct fluorescent antibody test (dFAT) or viral isolation in mice or cell culture can be difficult, and the application of molecular biological methods may be necessary. We performed an indirect rapid immunohistochemistry test (iRIT) for the detection of the rabies virus (RABV) antigen in the central nervous system (CNS) of equines and compare… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…Before use, bare ITO slices were ultrasonically cleaned by the ultrasonic cleaner (Reliance Digital, England) with an ultrasound frequency of 42 kHz with acetone, 1.0 M NaOH ethanol/water mixture (1:1, v/v), and DI water for 15 min. The samples were then dried at 90 • C. TiO 2 :C-NPs powder (4.0 mg) was ultrasonically dispersed in 2.0 mL of deionized water, and 20 µL of uniformly dispersed TiO 2 :C-NPs suspension (2.0 mg/mL) was drip-coated on an ITO electrode with a modified area of 0.25 cm 2 . After drying at room temperature, the sample was calcined in air at 450 • C for 30 min, and then slowly cooled to room temperature to obtain the resulting TiO 2 :C-NPs/ITO electrode.…”
Section: Fabrication Of Tio :C-nps/ito Electrodementioning
confidence: 99%
See 1 more Smart Citation
“…Before use, bare ITO slices were ultrasonically cleaned by the ultrasonic cleaner (Reliance Digital, England) with an ultrasound frequency of 42 kHz with acetone, 1.0 M NaOH ethanol/water mixture (1:1, v/v), and DI water for 15 min. The samples were then dried at 90 • C. TiO 2 :C-NPs powder (4.0 mg) was ultrasonically dispersed in 2.0 mL of deionized water, and 20 µL of uniformly dispersed TiO 2 :C-NPs suspension (2.0 mg/mL) was drip-coated on an ITO electrode with a modified area of 0.25 cm 2 . After drying at room temperature, the sample was calcined in air at 450 • C for 30 min, and then slowly cooled to room temperature to obtain the resulting TiO 2 :C-NPs/ITO electrode.…”
Section: Fabrication Of Tio :C-nps/ito Electrodementioning
confidence: 99%
“…Rabies is caused by the rabies virus (RABV), which infects the central nervous system of almost all mammals with a mortality rate of nearly 100% ( 1 ). Although several effective and fast diagnostic methods have been used to detect RABV ( 2 4 ), current methods are limited by the low abundance of RABV in brain tissue and/or saliva samples.…”
Section: Introductionmentioning
confidence: 99%