2016
DOI: 10.1016/j.heares.2016.05.017
|View full text |Cite
|
Sign up to set email alerts
|

Detection efficiency of auditory steady state evoked by modulated noise

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 28 publications
1
4
0
1
Order By: Relevance
“…John et al (2003), for instance, used noise with bandwidth from 1 to 8 kHz. Santos et al (2016) measured ASSR to three noise stimuli: two low-pass filtered noise stimuli with cutoff frequencies of 2 and 8 kHz and noise bandpass filtered from 2 to 8 kHz. In contrast, we investigated the effect of noise stimuli with much smaller bandwidths, thereby maintaining a frequency-specific assessment of the hearing.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…John et al (2003), for instance, used noise with bandwidth from 1 to 8 kHz. Santos et al (2016) measured ASSR to three noise stimuli: two low-pass filtered noise stimuli with cutoff frequencies of 2 and 8 kHz and noise bandpass filtered from 2 to 8 kHz. In contrast, we investigated the effect of noise stimuli with much smaller bandwidths, thereby maintaining a frequency-specific assessment of the hearing.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies have investigated the effect of stimulus bandwidth on the ASSR (John et al 1998(John et al , 2003Purcell et al 2004;Santos et al 2016). However, these studies used broadband stimuli (1 to 8 or 1 to 2 kHz) at relatively high presentation levels (55 to 70 dB SPL).…”
Section: Introductionmentioning
confidence: 99%
“…Modifications of the spectral composition and the amplitude envelopes of these standard stimuli have been proposed for optimizing the detection of ASSR [27, 66, 67]. Such modifications include the implementation of mixed amplitude and frequency modulated tones [68, 69], AM-tones with exponential envelopes [70, 71] and AM-noise [72]. Different physiological mechanisms underlie the increase in the ASSR amplitude resulting from the presentation of those “alternative” acoustic stimuli and that obtained by implementing a discrete stimulation mode.…”
Section: Discussionmentioning
confidence: 99%
“…Neste estudo foi utilizada a técnica de ORD Magnitude quadrática da Coerência (MSC) para a identificação da ASSR (Dobie and Wilson, 1989). A MSC foi escolhida pelo fato de apresentar o melhor desempenho em relação as demais técnicas de ORD na identificação da ASSR (Dobie and Wilson, 1993;Dobie and Wilson, 1994;Stürzebecher et al, 2001;Santos et al, 2016;Wianda and Ross, 2016).…”
Section: Magnitude Quadrática Da Coerência (Msc)unclassified