2019
DOI: 10.15587/1729-4061.2019.166375
|View full text |Cite
|
Sign up to set email alerts
|

Design of fire-resistant heat- and soundproofing wood wool panels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…In works [5,6] attention is paid to the physical and mechanical characteristics of composite board materials obtained on the basis of aluminosilicate adhesives, as well as similar materials with increased resistance to fire [7].…”
Section: Problem Descriptionmentioning
confidence: 99%
“…In works [5,6] attention is paid to the physical and mechanical characteristics of composite board materials obtained on the basis of aluminosilicate adhesives, as well as similar materials with increased resistance to fire [7].…”
Section: Problem Descriptionmentioning
confidence: 99%
“…Preparation of the binder consisted in bringing its viscosity to 10 s by the VZ-4 viscometer with water and applying it to the wood surface, modeling a certain construction product. Molding was performed in accordance with [15].…”
Section: Materials Used In the Experimentsmentioning
confidence: 99%
“…The values of the left side are determined from the formula (15), which includes experimentally measured values. Using the table, the corresponding value of B is found, which is an argument of the function ierfc, the value of which allows obtaining the formula for calculating the thermal diffusivity from the right side (15):…”
Section: Modeling Of Heat Transfer Parameters For Dead Pine Wood Consmentioning
confidence: 99%
See 1 more Smart Citation
“…The coating initially has the maximum value of flame-retardant efficiency with the same dynamics of its reduction; accordingly, it would have a lifetime that is much longer due to the reserve of the actual value of the efficiency parameter [1,2]. Given the different character of change in the flame retardant properties due to the conditions and operation duration, the ratio of coatings' service life might prove to be unpredictable, since wood can adsorb moisture from air, which could lead to loss of adhesion by the coating, as well as and its shedding [3,4]. In practice, it should be justified that a flame-retardant coating that provides for a certain…”
mentioning
confidence: 99%