2002 IEEE International Conference on Industrial Technology, 2002. IEEE ICIT '02.
DOI: 10.1109/icit.2002.1189312
|View full text |Cite
|
Sign up to set email alerts
|

Design and manufacturing of personalized implants and standardized templates for cranioplasty applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
3

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 13 publications
0
10
0
3
Order By: Relevance
“…With the use of a design support program and databases, basic data processing steps were automatically implemented, and the design time was, therefore, reduced to half a day. Finally, the implant is accurately designed, and only RP implant model is made from which the biocompatible implant is fabricated by RT techniques (Hieu et al, 2002b). Therefore, the total patient treatment cost is minimized.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…With the use of a design support program and databases, basic data processing steps were automatically implemented, and the design time was, therefore, reduced to half a day. Finally, the implant is accurately designed, and only RP implant model is made from which the biocompatible implant is fabricated by RT techniques (Hieu et al, 2002b). Therefore, the total patient treatment cost is minimized.…”
Section: Resultsmentioning
confidence: 99%
“…In the field of cranioplasty, the skull template was not only used for the modelling of the personalized implant as the design support data, but also for making standardised (cranioplasty) implants (Hieu et al, 2002b). The application of standardised implants for the cranioplasty treatment is the cheap technical solution; it provides surgeons a new surgical aid tool for preparing the implants; especially it is very useful for defect cases where the cosmetics are not highly required such as the ones in the hair-covered area.…”
Section: Minimizing the Cost Of Cranioplasty Implants Productionmentioning
confidence: 99%
“…17,19 However the ventricular auricular union can be identified seen from without and the mitral leaflets insertion zone from within, this is what is used in both CT and echo scans as a substitute for identifying the mitral ring.…”
Section: Image Capture Using Cardiac Ctmentioning
confidence: 98%
“…17,19 Nonetheless, the use of personalized prostheses or implants has historically been something occasional and practically always the result of research projects. This is basically due to the limits of cost and timeline problems that have prevented these personalized prostheses or implants from competing with standard mass-produced designs.…”
Section: New Possibilities Regarding the Development Of Personalized mentioning
confidence: 99%
“…The power of these software packages together with their ability to manage information from medical images as a basis for design, means that at present, customized designs, specially for the medical device industry, can be designed in a matter of hours, while comparing alternative designs is also made easier (Hieu, 2002, Harryson, 2007. However, the use of customized designs, products, prostheses or implants has been historically sporadic, practically always the fruit of research projects.…”
mentioning
confidence: 99%