2016
DOI: 10.1016/j.ejmp.2016.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Design and development of a dedicated portable gamma camera system for intra-operative imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 12 publications
(23 citation statements)
references
References 33 publications
0
8
0
1
Order By: Relevance
“…min min (6) The A min can then be correlated with the minimum required per kilo administered activity of 90 Y, estimated at the time of the intervention 2 :…”
Section: Ht Tummentioning
confidence: 99%
See 1 more Smart Citation
“…min min (6) The A min can then be correlated with the minimum required per kilo administered activity of 90 Y, estimated at the time of the intervention 2 :…”
Section: Ht Tummentioning
confidence: 99%
“…Established methods to date make use of a γ-emitting tracer and either a γ radiation detecting probe [3,4] or a portable gamma camera [5,6]. Since γ radiation can travel through a large amount of tissue, any uptake of the tracer in nearby healthy tissue represents a non-negligible background, limiting and sometimes preventing the use of this technique.…”
mentioning
confidence: 99%
“…Medipix2 photon counting readout chip. This imaging probealso adopted in an experimental CT/SPECT system dedicated to the breast [34], and for imaging at nuclear facilities [27,28] could be adopted for various tasks as preoperative or intraoperative SLN localization with 99m Tc radiotracer in breast cancer or melanoma patients [18,[35][36][37][38], breast imaging with 99m Tc-Sestamibi [39], thyroid imaging [40], breast RGS with 125 I and/or 99m Tc radiotracers [41], and in hybrid imaging systems [42]. The same detector unitdeveloped within the Medipix2 Fig.…”
Section: Introductionmentioning
confidence: 99%
“…Comparison of some performance parameters for commercial and experimental compact gamma cameras (adapted from Ref [36]…”
mentioning
confidence: 99%
“…To date, established methods make use of a γ-emitting tracer and a γ radiation detecting probe [3,4] or a portable gamma camera [5,6]. Since γ radiation can travel through large amounts of tissue, any uptake of the tracer in nearby healthy tissue represents a non-negligible background, strongly limiting and often preventing the use of this technique.…”
mentioning
confidence: 99%