2011
DOI: 10.1016/j.apenergy.2011.05.039
|View full text |Cite
|
Sign up to set email alerts
|

Defrosting method adopting dual hot gas bypass for an air-to-air heat pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 93 publications
(14 citation statements)
references
References 12 publications
0
11
0
Order By: Relevance
“…T f and T df correspond to the frosting and defrosting time in one operation cycle, respectively. Assuming that whether in frosting or defrosting process, the electricity consumption of compressor and the heat release of the condenser are stable in a certain time (ΔT f and ΔT df ), and the whole process is regarded as an approximate steady state process, and the systems EER f , EER df , and EER of the different processes are expressed as (6), (7), and (8), respectively.…”
Section: Experimental Apparatus and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…T f and T df correspond to the frosting and defrosting time in one operation cycle, respectively. Assuming that whether in frosting or defrosting process, the electricity consumption of compressor and the heat release of the condenser are stable in a certain time (ΔT f and ΔT df ), and the whole process is regarded as an approximate steady state process, and the systems EER f , EER df , and EER of the different processes are expressed as (6), (7), and (8), respectively.…”
Section: Experimental Apparatus and Proceduresmentioning
confidence: 99%
“…Therefore, the identification of the most suitable and effective defrosting method is of widespread concern. The defrosting methods mainly include hot water spray defrosting, electric heater defrosting, compressor shutdown, hot gas bypass and reverse‐cycle defrosting . A number of studies have experimentally investigated the defrosting methods and their effects .…”
Section: Introductionmentioning
confidence: 99%
“…Then a defrosting cycle combined dual hot gas bypass defrosting (DHBD) and the accumulator heating method was developed . Compared with HGBD method, DHBD method reduced the defrosting time by 36% …”
Section: Introductionmentioning
confidence: 99%
“…24 Compared with HGBD method, DHBD method reduced the defrosting time by 36%. 25 Phase change energy storage defrosting has also been widely studied. In recent years, performance improvement and energy demand reduction in refrigeration systems using phase change material (PCM) has attracted more attention.…”
Section: Introductionmentioning
confidence: 99%
“…In the refrigerating engineering field, Ma & Wang (2011) developed bypass check valve to enhance the overall system performance; Choi, B. Kim, Kang, & K. Kim (2011), and J. Kim, Choi, & K. Kim (2015) applied the bypass for defrosting in the heat pump; Tuo & Hrnjak (2012) showed that flash gas bypass method could improve refrigerant distribution and reduce pressure drop on refrigerant side in the mobile air conditioning system; Byun, Lee, & Jeon (2008) discovered that the hot gas bypass method was useful for retarding the formation and growth of frost at the outdoor coil and for improving the performance of the air source heat pump; Tso, Wong, Jolly, & Ng (2001) conducted simulation studies using a mathematical model to compare the performance of the hot-gas by-pass control and the suction modulation control in refrigerated shipping containers, their results showed that the suction modulation control strategy was the more energy efficient of the two; Elbel & Hrnjak (2004) found that the performance of transcritical R744 systems with direct expansion could be significantly improved by implementing a flash gas bypass; it was demonstrated by Wang, Han, Shi, & Li (2012) that suction gas bypass was an effective regulating method of scroll compressor, and it could reduce the inner compression loss under over compression conditions and largely decrease the heating/cooling capacity of the refrigeration system; used flash gas bypass for vapor-liquid separation in vapor compression systems; Huang, Li, & Yuan (2009) suggested that the hot-gas bypass defrosting could overcome the main disadvantages of the reverse-cycle defrosting method; Ding, Zhang, & Lu (2004) proved bypass two-circuit cycle freezers with one compressor were more efficient than two-evaporator in series cycle freezers in reducing the greenhouse gas emissions.…”
Section: Introductionmentioning