2014
DOI: 10.1109/tdei.2013.004163
|View full text |Cite
|
Sign up to set email alerts
|

Deconvolution techniques for space charge recovery using pulsed electroacoustic method in coaxial geometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
20
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(21 citation statements)
references
References 15 publications
1
20
0
Order By: Relevance
“…A typical experimental arrangement for cable geometry is shown in Figure 1 [14]. It consists of a cable sample with a measurement device composed by a PEA cell including piezo sensor and amplifier, a DSO (Digital Signal Oscilloscope), a HVDC generator and a pulse generator (50 ns width, 10 kHz frequency and up to 5 kV amplitude).…”
Section: Techniques and Methodologies For Space Charge Assessmentmentioning
confidence: 99%
See 2 more Smart Citations
“…A typical experimental arrangement for cable geometry is shown in Figure 1 [14]. It consists of a cable sample with a measurement device composed by a PEA cell including piezo sensor and amplifier, a DSO (Digital Signal Oscilloscope), a HVDC generator and a pulse generator (50 ns width, 10 kHz frequency and up to 5 kV amplitude).…”
Section: Techniques and Methodologies For Space Charge Assessmentmentioning
confidence: 99%
“…From there the transfer function of the system can be isolated, accounting for the cylindrical geometry and attenuation and dispersion of acoustic waves in the material. Acoustic signals recorded in specific conditions are treated to provide charge distributions as detailed e.g., in [8,14]. Features of the PEA method are the possibility of making acquisition with stress either on or off, its excellent time resolution, its relative lightness and the fact that it is widespread.…”
Section: Techniques and Methodologies For Space Charge Assessmentmentioning
confidence: 99%
See 1 more Smart Citation
“…(6)(7)(8)(9) Some researchers have begun to measure the space charge profiles in coaxial cables and achieved preliminary results. (10)(11)(12)(13)(14)(15)(16) For example, Fukunaga et al applied the high-frequency pulse to a cable conductor through a coupling capacitor. (11) Fu et al used a plate measuring electrode instead of circular one to realize the linear contact between cable samples and the measuring electrode.…”
Section: Introductionmentioning
confidence: 99%
“…In this PEA method, the pulse could couple into the cable without attenuation but with the damage of the cable structure. (13) Hozumi et al injected a pulse from the PEA measuring electrode insulated to the ground and then coupled into the cable conductor via bulk capacitance. An analog/digital (A/D) fiber optic linker was used to isolate the PEA measuring electrode and oscilloscope.…”
Section: Introductionmentioning
confidence: 99%