2010 2nd International Conference on Information Technology Convergence and Services 2010
DOI: 10.1109/itcs.2010.5581266
| View full text |Cite
|
Sign up to set email alerts
|
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 4 publications
0
4
0
1
Order By: Relevance
“…Prior works have developed watch-based PAT devices. The user touches the back of the watch with the opposing hand to obtain an ECG while LEDs are mounted to monitor wrist PPG [17, 38]. While this is a simple and convenient maneuver, the resulting BP measurement would be inaccurate in certain vasoactive interventions such as vasoconstriction [45].…”
Section: Related Workmentioning
confidence: 99%
“…Prior works have developed watch-based PAT devices. The user touches the back of the watch with the opposing hand to obtain an ECG while LEDs are mounted to monitor wrist PPG [17, 38]. While this is a simple and convenient maneuver, the resulting BP measurement would be inaccurate in certain vasoactive interventions such as vasoconstriction [45].…”
Section: Related Workmentioning
confidence: 99%
“…Its error rate was higher than the commercial products, but it was a novel attempt which could approach the reliability of traditional BP measurement devices. 28 Zakaria et al recorded the values of PWTT and SBP in three experiments. According to the results of the experiments, three di®erent mathematical equations for calculation of SBP from PWTT were obtained.…”
Section: Discussionmentioning
confidence: 99%
“…Source: Author Figure 4 shows the location in electrocardiogram time (above) and phototypesmogram (below) and from the presented graph, it can be seen that the distances between the vertices of the electrocardiogram, named RR intervals, coincide with the distance between the phototypesmogram peaks (PP intervals). According to the authors of Kim et al (2010) and Yoon et al (2009) it is possible to determine the blood pressure by the simultaneous use of an electrocardiogram and a phototypesmogram. For this purpose a method is used based on pulse wave delay, as measured by a photoplethysmograph, against the QRS complex of electrocardiogram.…”
Section: Principle оF Action Of Photoplethysmographic Methodsmentioning
confidence: 99%