Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…The AC input voltage of each phase satisfies Equation (1), and the relationship between the input current i abc and the voltage across the AC input reactor V Labc is expressed, as shown in Equation (2). [12][13][14] The 3-phase AC/DC PWM converter that is used for DC distribution is an AC/DC step-up converter that outputs a boost DC while using an appropriately designed AC input side reactor. Using this 3-phase AC/DC PWM converter, the grid side AC current can be maintained at a waveform that is close to a sinusoidal waveform with a relatively low total harmonic distortion (THD), and the power factor can be freely controlled.…”
Section: -Phase Ac/dc Pwm Converter Used In DC Distribution Systemmentioning
confidence: 99%
“…The AC input voltage of each phase satisfies Equation (1), and the relationship between the input current i abc and the voltage across the AC input reactor V Labc is expressed, as shown in Equation (2). [12][13][14] The 3-phase AC/DC PWM converter that is used for DC distribution is an AC/DC step-up converter that outputs a boost DC while using an appropriately designed AC input side reactor. Using this 3-phase AC/DC PWM converter, the grid side AC current can be maintained at a waveform that is close to a sinusoidal waveform with a relatively low total harmonic distortion (THD), and the power factor can be freely controlled.…”
Section: -Phase Ac/dc Pwm Converter Used In DC Distribution Systemmentioning
confidence: 99%
“…[7] Thus, we inhibited circulating current to control the power of parallel module by using (1). [8] In this paper, power conversion device is consisted of AC/DC PWM converter and bi-directional DC/DC converter as called 'module' and each 2 modules are separated as master module and slave module. Meanwhile, battery for BESS is Lithium-polymer battery that has capacity of 40[kWh], 150[Adc].…”
Section: A System Configurationmentioning
confidence: 99%
“…1 shows relations of power converters of DC distribution system and loads in general building. Three-phase AC/DC converter can obtain boosted DC power by AC power and control active and reactive power to AC grid [4] [8]. Also, DC distribution system can connect generated power of distributed generators with DC distribution grid through a minimum of power conversion step and construct more efficient system.…”
Section: Introductionmentioning
confidence: 99%