2018
DOI: 10.1016/j.jacr.2018.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Contemporary Interventional Radiology Dosimetry: Analysis of 4,784 Discrete Procedures at a Single Institution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
27
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 22 publications
(31 citation statements)
references
References 18 publications
1
27
3
Order By: Relevance
“…Recent data for P KA are available in the international literature for interventional fluoroscopy procedures. Among others, Peruzzo Cornetto et al tabulated data for 23 procedures in an Italian hospital, Compagnone et al published data from a different Italian hospital for nine interventional procedures, Dauer et al published P KA data for 43 interventional fluoroscopy procedures at a single U.S. institution, Bundy et al did the same for 12 procedures at a different U.S. medical center, Erskine et al published P KA data for 32 interventional fluoroscopy procedures in Australia, Étard et al’s report contains data from France for 15 procedures, Pitton et al published data for 17 interventional vascular procedures at a German hospital, Schmitz et al reported data on biliary interventions at 23 different facilities, and Ruiz‐Cruces et al reported data for seven interventional procedures performed at eight hospitals in Spain. Many other published studies were also consulted to estimate one or more of P KA , E , and DC E …”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Recent data for P KA are available in the international literature for interventional fluoroscopy procedures. Among others, Peruzzo Cornetto et al tabulated data for 23 procedures in an Italian hospital, Compagnone et al published data from a different Italian hospital for nine interventional procedures, Dauer et al published P KA data for 43 interventional fluoroscopy procedures at a single U.S. institution, Bundy et al did the same for 12 procedures at a different U.S. medical center, Erskine et al published P KA data for 32 interventional fluoroscopy procedures in Australia, Étard et al’s report contains data from France for 15 procedures, Pitton et al published data for 17 interventional vascular procedures at a German hospital, Schmitz et al reported data on biliary interventions at 23 different facilities, and Ruiz‐Cruces et al reported data for seven interventional procedures performed at eight hospitals in Spain. Many other published studies were also consulted to estimate one or more of P KA , E , and DC E …”
Section: Resultsmentioning
confidence: 99%
“…Clinical experience was used to interpret the procedure types and anatomic locations of the procedures for which radiation dose data were provided. The values reported for average E and suggested [5,7,9,10,13,16,23,24,27,28,30,31,61] 0.03-620.9 [5,9,13,16,23,[29][30][31] Percutaneous intestinal access 2.2-44.1 [5][6][7]9,13,24] 0.02-308.8 [5,9,13] Head and/or neck diagnostic angiography 21-242 [6,9,10,12,15,17,19,22,30,31] 13-4131 [9,12,17,19,22,30,31] Head…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations