2020
DOI: 10.5577/intdentres.2020.vol10.no2.5
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the resistance to cyclic fatigue of One Curve, One Shape, 2Shape and EdgeFile X3 files in simulated single and S-shaped (double) curvatures

Abstract: Aim: To evaluate the fracture resistance to cyclic fatigue of One Curve (Micro-Mega, Besancon, Cedex, France), One Shape (Micro-Mega), 2Shape (Micro-Mega) and EdgeFile X3 (EdgeEndo, Albuquerque, NM) files in simulated root canals. Methodology: One hundred and sixty nickel-titanium endodontic files were tested in simulated canals with single and s-shaped (double) curvatures. The One Curve (25/.06), One Shape (25/.06), 2Shape (25/.06) and EdgeFile X3 (25/.06) files were assessed (n=20 for each test). All t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 21 publications
1
3
0
Order By: Relevance
“…These differences can be related to the different thermal treatment approaches of alloys of the instruments subjected to the fatigue test. Previous investigations are in agreement with the findings, demonstrating superior or even exceptional resistance of the Fire-Wire™ NiTi alloy EdgeFiles to cyclic fatigue in comparison to other thermally treated or conventional NiTi instruments at the 37 • C testing temperature [37,38]. In this investigation, the EDM files demonstrated better resistance to cyclic fatigue in comparison with CM instruments, and these results are in concordance with previous findings [39].…”
Section: Discussionsupporting
confidence: 92%
“…These differences can be related to the different thermal treatment approaches of alloys of the instruments subjected to the fatigue test. Previous investigations are in agreement with the findings, demonstrating superior or even exceptional resistance of the Fire-Wire™ NiTi alloy EdgeFiles to cyclic fatigue in comparison to other thermally treated or conventional NiTi instruments at the 37 • C testing temperature [37,38]. In this investigation, the EDM files demonstrated better resistance to cyclic fatigue in comparison with CM instruments, and these results are in concordance with previous findings [39].…”
Section: Discussionsupporting
confidence: 92%
“…If Af is higher than the body temperature, the file will be in a mixed martensitic state, Rphase and austenitic structure. 5 Therefore, heat treated files demonstrated a significant increase in flexibility and flexural fatigue resistance in intra-canal temperature.…”
Section: Introductionmentioning
confidence: 99%
“…EdgeFile system was manufactured using Firewire technology that is responsible for its improved CFR over the other file systems. [ 24 ]…”
Section: Discussionmentioning
confidence: 99%