2010
DOI: 10.1016/j.radonc.2010.02.026
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of optimized single and multifield irradiation plans of antiproton, proton and carbon ion beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
23
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(23 citation statements)
references
References 27 publications
0
23
0
Order By: Relevance
“…These studies indicate that dose verification to ~1 mm accuracy would be possible within a therapeutic dose range1819. However, concerns about this long range secondary radiation have been raised as it would inevitably decrease the resolution of the dose deposition profiles which is one of the main advantages of ion beam therapy202122. It is however, recognized that the resolution of the dose profiles will have to be assessed for the biological effective dose, including RBE profiles, requiring detailed investigations of the biological consequences of antiproton exposures.…”
mentioning
confidence: 99%
“…These studies indicate that dose verification to ~1 mm accuracy would be possible within a therapeutic dose range1819. However, concerns about this long range secondary radiation have been raised as it would inevitably decrease the resolution of the dose deposition profiles which is one of the main advantages of ion beam therapy202122. It is however, recognized that the resolution of the dose profiles will have to be assessed for the biological effective dose, including RBE profiles, requiring detailed investigations of the biological consequences of antiproton exposures.…”
mentioning
confidence: 99%
“…The capability of FLUKA for proton therapy calculations has been validated in a number of studies. ( 29 32 ) The model of the beam used in simulation of the range shift experiments with pure materials was verified by independent measurements on depth‐dose distribution in a water equivalent phantom.…”
Section: Methodsmentioning
confidence: 95%
“…In SHIELD-HIT10A, the ripple filter or similar structures periodic in one dimension can be simulated by providing an extra file containing the periodic structure and the position. The ripple filter is implemented in a similar way as described by Bassler et al (2010): In the geometry, the ripple filter is simply modeled as a solid block of material. However, when the particles hit this block, they are displaced along the z axis corresponding to the varying thickness of the ripple structure.…”
Section: Methodsmentioning
confidence: 99%