2004
DOI: 10.1081/jlc-200034876
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Fluorescence Immunochromatography and HPLC for the Trace Analysis of Algal Toxins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…Moreover, Pyo et al (Pyo, Choi et al 2004) applied a lateral flow device (LFD) for measuring MC and the assay had the LOD of 200 pg mL −1 and was able to detect all the main MCs (Pyo, Choi et al 2004). …”
Section: Labels For Immunochromatographic Assaysmentioning
confidence: 98%
See 1 more Smart Citation
“…Moreover, Pyo et al (Pyo, Choi et al 2004) applied a lateral flow device (LFD) for measuring MC and the assay had the LOD of 200 pg mL −1 and was able to detect all the main MCs (Pyo, Choi et al 2004). …”
Section: Labels For Immunochromatographic Assaysmentioning
confidence: 98%
“…However, the better sensitivity could be the result of the fact that the fluorescent LFD was provided with instrumental detection whereas results from GNP-based LFD were evaluated visually, which reduces detectability (Pyo, Choi et al 2004). …”
Section: Labels For Immunochromatographic Assaysmentioning
confidence: 99%
“…Double extraction with 75% methanol was also employed for homogenates of algae and fish tissue [37]. In another procedure, extraction of cells with 25% methanol [27] or 5% acetic acid [16] is assisted by sonication, whereas in another one proportion 50% methanol and 50% acetic acid was found as the best [47]. The use of acetic acid instead of methanol is advantageous because of more efficient elimination of proteins and possibility of direct use of extracts for preconcentration on C18 sorbents.…”
Section: Preconcentration Of MC and Clean-up Of Analyzed Samplesmentioning
confidence: 98%
“…On such sorbents MC were extracted from aqueous solutions and then eluted with methanol [25,27,40,47,54,56,61]. In combined procedures for the determination of MC in waters, the samples were first screened using protein phosphatase assays and positives were concentrated using SPE on Bakerbond C18 Polarplus sorbent, which was selected as optimum of seven different sorbents examined [44].…”
Section: Preconcentration Of MC and Clean-up Of Analyzed Samplesmentioning
confidence: 99%
See 1 more Smart Citation