2021
DOI: 10.1148/ryct.2021200503
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of CT Lung Density Measurements between Standard Full-Dose and Reduced-Dose Protocols

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 29 publications
1
7
0
Order By: Relevance
“…Deployer chest HRCT scans were acquired on either a Siemens Sensation 64 or Siemens AS 128 scanner using a standardized protocol, as used in Phase 3 of the COPDGene Study 22 . Thin sections (0.5 to 0.75 mm slice thickness) with a moderately high spatial frequency reconstruction algorithm were used to enhance parenchymal and small airways findings.…”
Section: Methodsmentioning
confidence: 99%
“…Deployer chest HRCT scans were acquired on either a Siemens Sensation 64 or Siemens AS 128 scanner using a standardized protocol, as used in Phase 3 of the COPDGene Study 22 . Thin sections (0.5 to 0.75 mm slice thickness) with a moderately high spatial frequency reconstruction algorithm were used to enhance parenchymal and small airways findings.…”
Section: Methodsmentioning
confidence: 99%
“…All HRCT scans were acquired using the same reduced-dose protocol as that used in Phase 3 of the COPDGene © study [ 39 ]. Thin sections (0.5–0.75 mm slice thickness) with a high spatial frequency reconstruction algorithm were used to enhance parenchymal and small airways findings.…”
Section: Methodsmentioning
confidence: 99%
“…Emphysema predominant phenotype was defined as ≥ 10% low attenuation areas based on LAA%-950. A cut point of 5% has been suggested for higher dose CT imaging that was typical with earlier generations of equipment, but recent work suggests that a greater cut point is more appropriate for reduced dose images, as were used in this study [ 15 , 39 ].…”
Section: Methodsmentioning
confidence: 99%
“…𝑣 2 is the noise variance in the equation above and was set according to the global noise index measured from the input data using the method described in [10].…”
Section: Physics-based Harmonizermentioning
confidence: 99%
“…It causes a decrease in respiratory lung function and shortness of breath, which gets worse with activity. The presence and severity of emphysema are associated with physiologic impairment, risk of exacerbation of COPD, and mortality [2]. Computed tomography (CT) has been an important screening tool for non-invasive disease assessment.…”
Section: Introductionmentioning
confidence: 99%