Comparison of air displacement plethysmography with dual-energy X-ray absorptiometry and 3 field methods for estimating body composition in middle-aged men

Abstract: This study was designed to compare air displacement plethysmography with dual-energy X-ray absorptiometry (DXA) and 3 other field methods for estimation of body composition. Subjects were 62 healthy, white men aged 37.6+/-2.9 y (weight: 81.8+/-11.3 kg; height: 171.5+/-4.9 cm). Body composition was also assessed by using body mass index, single-frequency bioelectrical impedance analysis, multi-frequency bioelectrical impedance spectroscopy, and the skinfold-thickness equations of Jackson and Pollock and Durnin … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
67
4
1

Year Published

2001
2001
2018
2018

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 120 publications
(81 citation statements)
references
References 30 publications
9
67
4
1
Order By: Relevance
“…4,6,11,18,19,25 These values are also probably dependent to some extent on prevailing ambient conditions and variations in the performance of individual instruments, although the latter should be minimized as each instrument is of a standard manufactured by a single company. Accordingly, a variable level of precision (although even the worst case was still very good) has been observed in a number of different subjects undergoing repeated measurements in other studies ( JCK Wells and JE Williams, unpublished).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4,6,11,18,19,25 These values are also probably dependent to some extent on prevailing ambient conditions and variations in the performance of individual instruments, although the latter should be minimized as each instrument is of a standard manufactured by a single company. Accordingly, a variable level of precision (although even the worst case was still very good) has been observed in a number of different subjects undergoing repeated measurements in other studies ( JCK Wells and JE Williams, unpublished).…”
Section: Discussionmentioning
confidence: 99%
“…Various studies have assessed the accuracy of body composition estimates obtained with ADP against established techniques, such as HW, in both adults [3][4][5][6][7][8][9][10][11][12] and children. 5,6,10,13,14 However, although reported estimates of mean differences (biases) between HW and ADP are generally relatively small, there are inconsistencies in the observed direction of these biases and wide variation for individuals, as shown by a large range for the limits of agreement between methods (for review, see Fields 15 ).…”
Section: Introductionmentioning
confidence: 99%
“…This method has been reported to agree closely with the traditional gold standard hydrodensitometry (underwater weighing). Furthermore, the Bod-Pod ® has been shown to predict fat mass and fat-free mass more accurately than dual-energy X-ray absorptiometry and bioelectrical impedance [15][16][17].…”
Section: Anthropometric Measurementsmentioning
confidence: 99%
“…BOD POD; Life Measurement Incorporated, Concord, CA, USA), in part because of its wide applicability to many diverse populations and its relative ease both on the subject and tester as compared with more traditional techniques. This equipment has been widely validated against reference methods in healthy children, adolescents, adults and elderly (Sardinha et al, 1998;Collins et al, 1999;Levenhagen et al, 1999;Miyatake et al, 1999;Nunez et al, 1999;Wagner et al, 2000;Fields et al, 2001;Millard-Stafford et al, 2001;Bosy-Westphal et al, 2003;Silva et al, 2006). Furthermore, test-retest reliability, between-day variability, within-subject variability and between-instrument variability appear to be good to excellent (Fields et al, 2002;Ball, 2005;Going, 2005).…”
Section: Introductionmentioning
confidence: 99%