Comparison of a R744 cascade refrigeration system with R404A and R22 conventional systems for supermarkets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
21
0
4

Year Published

2014
2014
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 67 publications
(25 citation statements)
references
References 5 publications
0
21
0
4
Order By: Relevance
“…This was experimentally verified by da Silva et al [6] in a pilot supermarket plant, where a R404A/CO2 cascade plant offered 22.3 % reduction of electricity consumption during a year of operation regards a conventional R404A direct expansion configuration.…”
Section: Introductionmentioning
confidence: 64%
“…This was experimentally verified by da Silva et al [6] in a pilot supermarket plant, where a R404A/CO2 cascade plant offered 22.3 % reduction of electricity consumption during a year of operation regards a conventional R404A direct expansion configuration.…”
Section: Introductionmentioning
confidence: 64%
“…W kaskadowym sprężarkowym układzie chłodniczym z dwoma niezależnymi obiegami z dwoma różnymi czynnikami gdzie dwa media transportujące ciepło są połączone wymiennikiem ciepła, który pełni funkcję parownika dla jednego skraplacza dla drugiego czynnika. W takim rozwiązaniu temperatura osiągnięta na dolnym stopniu kaskady może być znacząco poniżej -80 0 C [6,11]. Dwutlenek węgla w rozwiązaniach chłodniczych jest także często używanym czynnikiem, ale ze względu na jego niską temperaturę krytyczną wymaga wysokiego ciśnienia sprężania dlatego w pewnych rozwiązaniach konieczna jest praca w układzie nadkrytycznym.…”
Section: Wstępunclassified
“…Furthermore, heat recovery from the CO 2 booster system is proved to satisfy 40% of space heating in the modeled supermarket. In another study based on laboratory measurements of three systems installed in Brazil, performance of a cascade R404A/CO 2 was compared with single stage multiplex R404A and R22 supermarket refrigeration systems [9]. The annual electricity use of the cascade system is measured to be 22.3% less than the R404A system and 13.7% less than the R22 system.…”
Section: Introductionmentioning
confidence: 99%
“…10 Systems with the same medium and low temperature levels COP's but with different load ratios will have different total COP's. in equation 9 can be substituted with its equivalent in equation 10. 11 For and , the cooling capacities over the corresponding medium and low temperature levels COP's can be used.…”
mentioning
confidence: 99%
See 1 more Smart Citation