2023
DOI: 10.1016/j.bios.2022.114913
|View full text |Cite
|
Sign up to set email alerts
|

Combinatorial perturbation sequencing on single cells using microwell-based droplet random pairing

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…A microwell array device was used for droplet pairing and merging, as previously described. 23 Each microwell unit was composed of a large well (Φ90 μm) and a small well (Φ50 μm) that were interconnected, and the depths were 70 and 50 μm, respectively. As shown in Figure 1b,c and Video S1, primer droplets (∼Φ90 μm) were first loaded into the microwell array device and occupied the large well of each microwell unit.…”
Section: ■ Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A microwell array device was used for droplet pairing and merging, as previously described. 23 Each microwell unit was composed of a large well (Φ90 μm) and a small well (Φ50 μm) that were interconnected, and the depths were 70 and 50 μm, respectively. As shown in Figure 1b,c and Video S1, primer droplets (∼Φ90 μm) were first loaded into the microwell array device and occupied the large well of each microwell unit.…”
Section: ■ Resultsmentioning
confidence: 99%
“…The primer droplets could be stored at 4 °C for at least 5 days without obvious coalescence (Figure S2). A microwell array device was used for droplet pairing and merging, as previously described . Each microwell unit was composed of a large well (Φ90 μm) and a small well (Φ50 μm) that were interconnected, and the depths were 70 and 50 μm, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The PDMS chips were then cut into the desired shape with a cutter knife, and holes were punched at the inlet and outlet of the chip with differently sized punches. For the parameters for fabricating the droplet-generating chip, please refer to a previous paper 54 . As for the picoinjection chip, Figure S3 shows the design parameters; the diameter of the holes of all inlets and outlets was 1 mm.…”
Section: Methodsmentioning
confidence: 99%
“…Microwell arrays have also been developed for isolating single cells. [47][48][49] By designing micropores or chambers that match the size of cells, cells randomly settle into the micropores due to their own gravity, with advantages of easy microfabrication and convenient operation. Feng et al proposed a microwell array for the quantitative detection of glucose phosphate by MS in single cells (Figure 2B).…”
Section: Microfluidicsmentioning
confidence: 99%