2015
DOI: 10.1016/j.crhy.2015.07.009
|View full text |Cite
|
Sign up to set email alerts
|

Coils for ingestible capsules: Near-field magnetic induction link

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…Table 4 summarizes the electrical properties with frequency changes in skin, fat, and muscle layers. [149][150][151][152][153][154][155] This table indicates that the overall decreasing and growing trends of relative permittivity and conductivity change with increasing frequencies, separately. Therefore, it is pervasively agreed to select the optimal operational frequency at relatively low frequencies to maintain safe tissue absorption and minimal power loss.…”
Section: Sarmentioning
confidence: 99%
“…Table 4 summarizes the electrical properties with frequency changes in skin, fat, and muscle layers. [149][150][151][152][153][154][155] This table indicates that the overall decreasing and growing trends of relative permittivity and conductivity change with increasing frequencies, separately. Therefore, it is pervasively agreed to select the optimal operational frequency at relatively low frequencies to maintain safe tissue absorption and minimal power loss.…”
Section: Sarmentioning
confidence: 99%
“…In this paper we focus on two configurations, parallel (θ=0°) and perpendicular (θ=90°), corresponding respectively to the best and the worst geometrical configuration between the reader and the tag loops in the case of RFID detection. Some studies were proposed in the literature optimizing the mutual coupling between the reader and the tag by changing either the sizes of antennas or theirs geometrical structures from a mono-layer loop to multi layer loops [3] [7] in the parallel configuration. However such studies did not solve the question of detection with a mono-layer 2D structure with other configurations, especially perpendicular configuration.…”
Section: Contextmentioning
confidence: 99%
“…The calculation of the mutual inductance under Matlab is based on the magnetic field (B r , B θ , B y ) generated by a current circulation, as defined by (3). The evaluation of M eq is achieved by a numerical discrete integration on a surface corresponding to the reader loop surface and orientation [7][8]. (3)…”
Section: IIImentioning
confidence: 99%
“…Besides on-board energy sources, remote powering of ingestible capsules using wireless power transmission have been investigated by researchers [59,160]. In one approach, a Helmholtz transmitting coil was attached to the patient and a ferrite-core three-dimensional receiving coil was placed in the capsule.…”
mentioning
confidence: 99%