2006
DOI: 10.1016/j.snb.2005.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Cobalt(II)-selective electrode based on a newly synthesized macrocyclic compound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 55 publications
(20 citation statements)
references
References 18 publications
0
20
0
Order By: Relevance
“…In addition, the nature of plasticizer is well-known to influence largely the measuring concentration range of the solvent polymeric sensors as well as their selectivity coefficients [12][13][14][15][16][17][18][19][20][21][22][23][29][30][31][32][33][34][35][36][37][38]52].…”
Section: Effect Of Membrane Compositionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the nature of plasticizer is well-known to influence largely the measuring concentration range of the solvent polymeric sensors as well as their selectivity coefficients [12][13][14][15][16][17][18][19][20][21][22][23][29][30][31][32][33][34][35][36][37][38]52].…”
Section: Effect Of Membrane Compositionmentioning
confidence: 99%
“…Thus, due to the urgent need for specific monitoring of Co 2+ ion in many industrial, environmental medicinal and food samples, there have been a number of recent reports on potentiometric cobalt ion-selective electrodes in the literature [29][30][31][32][33][34][35][36][37][38]. However, most of these electrodes possess either one, two or, in some cases, all of the following drawbacks: (1) narrow working concentration range, (2) high limit of detection and (3) significant interferences from many cations.…”
Section: Introductionmentioning
confidence: 99%
“…The measurement of the electromotoric force of the system with cobalt electrode, reference electrode Orion 90-02 was carried out at room temperature in a solution stirred with a mechanic stirrer by means of potentiometric system consisting of a custom made 16 …”
Section: Apparatusmentioning
confidence: 99%
“…So far only limited number of cobalt-selective sensors has been described in the literature on the topic [9][10][11][12][13][14][15][16][17]. Moreover, most of these electrodes suffer a lack of stability, a limited concentration range with theoretical response, and exhibit low lifetime and high response time.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation