CO2 laser surface treatment of failed dental implants for re-implantation: an animal study

Abstract: The aim of the present study was to evaluate the success rate of failed implants re-implanted after surface treatment with CO2 laser. Despite the widespread use of dental implants, there are many incidents of failures. It is believed that lasers can be applied to decontaminate the implant surface without damaging the implant. Ten dental implants that had failed for various reasons other than fracture or surface abrasion were subjected to CO2 laser surface treatment and randomly placed in the maxillae of dogs. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…The present study was an experimental and laboratory type of study. Considering the significance level of 5% and the test power of 80% and according to the results of previous studies (10) and the standard deviation S = 0.01 and to achieve a difference of 10% in the mean attachment in each group, 12 samples are required.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The present study was an experimental and laboratory type of study. Considering the significance level of 5% and the test power of 80% and according to the results of previous studies (10) and the standard deviation S = 0.01 and to achieve a difference of 10% in the mean attachment in each group, 12 samples are required.…”
Section: Methodsmentioning
confidence: 99%
“…Since 100 mj / pulse power is probably more efficient in removing microbial plaque, Er-YAG laser 100 mj / pulse irradiation is recommended for treating peri-implantitis. However, 60 mj / pulse irradiation had no adverse effect on the biocompatibility of the implant (10). Listl et al (2015) attempted to evaluate the cost-effectiveness of various nonsurgical methods in treating peri-implantitis.…”
Section: Introductionmentioning
confidence: 99%
“…OMIs Surface modification have to be more recommended for improving their stability and the compensation for lack of other factors through increasing bone to mini-implants contact (BIC) and removal torque values (RTv). OMIs surface treatments required several techniques included sandblasting, acid-etching, anodization and laser surface treatment techniques (6)(7)(8)(9)(10) . This study o Ahmed Safwat Mohamed (1) , Noha El-Wassefy (2) , Marwa Ali Tawfik (3) , Mona Abdelaziz Montasser (4) Ahmed Safwat Mohamed examined the effects of SLAO surface treatment versus CO 2 laser surface treatment of OMIs.…”
Section: Introductionmentioning
confidence: 99%