Clinical evaluation of 3 types of plate osteosynthesis for fixation of condylar neck fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
63
2
2

Year Published

2002
2002
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 113 publications
(79 citation statements)
references
References 12 publications
1
63
2
2
Order By: Relevance
“…Hardware failure in our study was 0%. Contrastingly in other studies, 24 plate fracture was exclusively observed in cases stabilized with single miniplate. The reason for hardware failure may be that this plate is located on the compression strain lines when placed conventionally along the condylar neck and goes completely against the principles of functionally stable osteosynthesis.…”
Section: Discussioncontrasting
confidence: 97%
See 1 more Smart Citation
“…Hardware failure in our study was 0%. Contrastingly in other studies, 24 plate fracture was exclusively observed in cases stabilized with single miniplate. The reason for hardware failure may be that this plate is located on the compression strain lines when placed conventionally along the condylar neck and goes completely against the principles of functionally stable osteosynthesis.…”
Section: Discussioncontrasting
confidence: 97%
“…Alternatively, a single 2.4 mm plate or a single 2.0 mm mini-dynamic compression plate may be used for fixation of condylar fractures, as they offer more resistance to rotation and 3-point bending. 14,15 However, in the condylar neck, the amount of bone is not always adequate to permit placement of 2-3 screws per fragment. To overcome this problem, various plate designs have been put forward.…”
Section: Introductionmentioning
confidence: 99%
“…The approximation of fracture fragments, plate fracture and screw loosening on radiographs (OPG) were evaluated at intervals of 24 h, 2 and 6 months postoperatively. In all cases, the radiographs revealed proper approximation of fracture fragments with good bone healing as shown by Choi et al [37]. No evidence of plate exposure, and screw loosening at fracture site was observed but this is not compatible with the findings of Choi et al [37].…”
Section: Discussionmentioning
confidence: 57%
“…Obviously, a two-plate technique is better if there is adequate bony substance on either side of the fracture line 15) . However, fixation with two miniplates might be a more traumatic procedure than fixation with a single miniplate 16,17) . Ellis and Walker reported that the single miniplate is the simplest and most reliable technique 18) .…”
Section: Discussionmentioning
confidence: 99%