2011
DOI: 10.1016/j.ijrobp.2010.10.016
|View full text |Cite
|
Sign up to set email alerts
|

Choreographing Couch and Collimator in Volumetric Modulated Arc Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
118
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 64 publications
(122 citation statements)
references
References 36 publications
(37 reference statements)
3
118
1
Order By: Relevance
“…Technically, however, it is already possible to realize arbitrary noncoplanar irradiation trajectories through simultaneous rotation of couch and gantry with a conventional linear accelerator (which may require access to a research mode of operation). 45 For step&shoot IMRT, it has been established that such noncoplanar irradiation fields may allow for substantial dose reductions in OARs, especially if the OARs are close to irregularly shaped target volumes that are located asymmetrically within the body. [46][47][48][49] Leaving potential issues regarding patient immobilization on a robotic couch aside, the first treatment planning studies investigating noncoplanar VMAT have reconfirmed a benefit of noncoplanar irradiation with regard to OAR sparing.…”
Section: E Noncoplanar Generalizations Of Vmatmentioning
confidence: 99%
See 2 more Smart Citations
“…Technically, however, it is already possible to realize arbitrary noncoplanar irradiation trajectories through simultaneous rotation of couch and gantry with a conventional linear accelerator (which may require access to a research mode of operation). 45 For step&shoot IMRT, it has been established that such noncoplanar irradiation fields may allow for substantial dose reductions in OARs, especially if the OARs are close to irregularly shaped target volumes that are located asymmetrically within the body. [46][47][48][49] Leaving potential issues regarding patient immobilization on a robotic couch aside, the first treatment planning studies investigating noncoplanar VMAT have reconfirmed a benefit of noncoplanar irradiation with regard to OAR sparing.…”
Section: E Noncoplanar Generalizations Of Vmatmentioning
confidence: 99%
“…[46][47][48][49] Leaving potential issues regarding patient immobilization on a robotic couch aside, the first treatment planning studies investigating noncoplanar VMAT have reconfirmed a benefit of noncoplanar irradiation with regard to OAR sparing. 33,45,47,[50][51][52][53] From the mathematical and technical side, the optimization of an irradiation trajectory shares the known issues of beam angle optimization (BAO) for step&shoot IMRT. When viewed as a continuous optimization problem, BAO is highly nonconvex.…”
Section: E Noncoplanar Generalizations Of Vmatmentioning
confidence: 99%
See 1 more Smart Citation
“…With the exception of Yang et al (2011), all trajectories were user-defined and therefore notionally 'arbitrary'. Yang et al identified optimal individual source positions using a beam's eye view volumetrics technique , Myrianthopoulos et al 1992, McShan et al 1995.…”
Section: Introductionmentioning
confidence: 99%
“…Different combinations of collimator and couch angles will result in different tracking complexity which affects the delivery performance. Therefore, optimization of collimator and couch trajectories may reduce the possibility of having plans running at the mechanical limits of the linac, which can improve the treatment efficiency and robustness 36, 37. In most published studies on VMAT plans with motion tracking, collimator, and couch angles for plans were set at 90° and 0°, respectively, which has been shown to be favorable for MLC tracking because the MLC leaf motion direction is parallel to target motion in superior‐inferior (SI) direction 30, 32, 34, 35.…”
Section: Introductionmentioning
confidence: 99%