Chemiluminescence Resonance Energy Transfer Competitive Immunoassay Employing Hapten-Functionalized Quantum Dots for the Detection of Sulfamethazine

Abstract: We describe a new strategy for using chemiluminescence resonance energy transfer (CRET) by employing hapten-functionalized quantum dots (QDs) in a competitive immunoassay for detection of sulfamethazine (SMZ). Core/multishell QDs were synthesized and modified with phospholipid-PEG. The modified QDs were functionalized with the hapten 4-(4-aminophenyl-sulfonamido)butanoic acid. The CRET-based immunoassay exhibited a limit of detection for SMZ of 9 pg mL(-1), which is >4 orders of magnitude better than a homogen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 44 publications
(12 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…GNPs and polymer-modified core/multishell QDs were previously prepared by our group. , Goat anti-mouse immunoglobulin G (IgG) was from Jackson Immuno-Research Laboratories (West Grove, PA). Bovine serum albumin (BSA) was from Sigma-Aldrich.…”
Section: Methodsmentioning
confidence: 99%
“…GNPs and polymer-modified core/multishell QDs were previously prepared by our group. , Goat anti-mouse immunoglobulin G (IgG) was from Jackson Immuno-Research Laboratories (West Grove, PA). Bovine serum albumin (BSA) was from Sigma-Aldrich.…”
Section: Methodsmentioning
confidence: 99%
“…More recently, more CRET platforms with traditional CL systems using luminophor donors and with metal‐based QDs as energy acceptors have been extensively reported . Suh and Park's group designed a reactive oxygen species (ROS)‐responsive hybrid nanoparticles (HNPs) composed of polyethylene glycol (PEG)‐modified QDs (PEG−QDs) that acted as energy acceptors and using a luminol derivative (L012)‐based CL system as the CRET donor.…”
Section: Semiconductor Quantum Dotsmentioning
confidence: 99%
“…11,12 Although these methods are standardized, accurate and reliable, their wide applications are limited by high costs and complex sample preparations. 13 In addition, antibody-dependent methods including enzyme-linked immunosorbent assay (ELISA), 14 chemiluminescence, 15 time-resolved immunoassay, 16,17 lateral flow immunoassay 18 and electrochemical immunosensor 19 also face different challenges such as poor stabilities, high costs, and difficulties in modifying antibody structures. 20 Aptamers are single-stranded DNA or RNA that bind specifically to target molecules, and they are selected by an in vitro process called systematic evolution of ligands by exponential enrichment (SELEX).…”
Section: Introductionmentioning