2018
DOI: 10.1016/j.nima.2018.01.037
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of the new neutron imaging and materials science facility IMAT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
70
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 58 publications
(77 citation statements)
references
References 24 publications
2
70
0
Order By: Relevance
“…We acquired energy-resolved neutron images at the IMAT beamline at the pulsed neutron facility ISIS, UK. (10,11) In this experiment, the neutron flux was roughly 5 × 10 6 n/cm 2 /s. The neutron wavelength can be determined by the neutron time-of-flight method using a timeresolving detector.…”
Section: Energy-resolved Neutron Imagingmentioning
confidence: 87%
“…We acquired energy-resolved neutron images at the IMAT beamline at the pulsed neutron facility ISIS, UK. (10,11) In this experiment, the neutron flux was roughly 5 × 10 6 n/cm 2 /s. The neutron wavelength can be determined by the neutron time-of-flight method using a timeresolving detector.…”
Section: Energy-resolved Neutron Imagingmentioning
confidence: 87%
“…The 'register' feature is sensor-level memory allowing up to 4 events per pixel to be buffered between readout operations. This paper focuses on the recent use of the detector at two time-offlight imaging beamlines: IMAT [3] at the ISIS source, UK, and the ESS test beamline V20 [4] located at HZB, Germany. In the case of IMAT, where the detector is available to the user programme, further detail is provided to describe integration into the existing beamline infrastructure.…”
Section: Introduction To Gp2mentioning
confidence: 99%
“…The fast development of TOF imaging is driven by the need for advanced materials research. In the past decade there have been significant developments in the design and installation of new imaging instruments on the one hand [2,[25][26][27][28][29], and advances with detection systems on the other hand [30][31][32][33]. Accordingly, the available instruments and methods have made substantial progress since the early feasibility studies using a gated CCD camera [1].…”
Section: Introductionmentioning
confidence: 99%
“…Accordingly, the available instruments and methods have made substantial progress since the early feasibility studies using a gated CCD camera [1]. Notably, two dedicated neutron imaging user facilities have been constructed at pulsed sources, namely RADEN [2] at J-PARC and IMAT [25,26,29] at ISIS. IMAT was installed on the 10 Hz pulsed source of the ISIS second target station at the Rutherford Appleton Laboratory, with substantial in-kind contributions from the Italian CNR.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation