2003
DOI: 10.1023/a:1024931913643
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of interconnect interfacial adhesion by cross-sectional nanoindentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 10 publications
0
8
0
Order By: Relevance
“…It is also important to understand delamination and cracking mechanisms as they are often incorporated with adhesion 30 testing. (Sanchez, 1999;Scherban, 2003, Chen, 2011Lu, 2011;Gerberich, 2011, Roshangias, 2015…”
Section: Mechanical Characterization Methods For Thin Films and Intermentioning
confidence: 99%
See 1 more Smart Citation
“…It is also important to understand delamination and cracking mechanisms as they are often incorporated with adhesion 30 testing. (Sanchez, 1999;Scherban, 2003, Chen, 2011Lu, 2011;Gerberich, 2011, Roshangias, 2015…”
Section: Mechanical Characterization Methods For Thin Films and Intermentioning
confidence: 99%
“…Practical work of adhesion can be evaluated from the nanoindentation-induced blister (NIB) test (Gerberich, 2006;Chen, 2011) where a mechanically stable crack is introduced to the interface by nanoindentation and characterized from the top by electron microscopy. A more detailed side view of the interfacial characteristics can be obtained using cross-sectional nanoindentation developed by Sanchez et al (Sanchez, 1999;Scherban, 2003;Zheng, 2005;Roshangias, 2015).…”
Section: Loading To the Top Of The Film-substrate Interfacementioning
confidence: 99%
“…However, tape testing is a qualitative measurement and a passing result is typically viewed as insufficient evidence for eventual success in a fully integrated interconnect. 196,197 More stringent and quantitative adhesive / interfacial toughness measurement techniques have been developed such as nanoindentation, 197,198 superlayer/buckle, [189][190][191][192] and scratch testing. 199,200 However, the predominate test utilized in the low-k/Cu interconnect community has been four point bend (4 pb) testing.…”
Section: -122mentioning
confidence: 99%
“…Based on the linear elastic fracture mechanics and plate theory, the interfacial critical energy release rate was calculated [55,56]. CSN was often used for identifying the weakest interface in multilayer structures and for characterizing interfacial adhesion [13,[56][57][58]. Compared with conventional testing methods, CSN presents some advantages.…”
Section: Interfacial Failure Induced By Substrate Crackingmentioning
confidence: 99%