Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system

Abstract: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance after exercise demands specific quality assurance measures.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
27
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 28 publications
(30 citation statements)
references
References 24 publications
3
27
0
Order By: Relevance
“…On the other hand, the penumbrae formed by the leaf sides (along the Y ‐axis) were wider on the +Y sides of the leaves than they were on the −Y sides. This asymmetry was regarded as resulting from the leaf bank tilt 24. These penumbra width results are similar to those reported by Fürweger et al24 Furthermore, although the discrepancies between the measured and calculated widths of the X ‐axis penumbrae were relatively small (maximum, 0.3 mm), those between the measured and calculated widths of the Y ‐axis penumbrae were large (maximum, 0.7 mm) when the MLC was used.…”
Section: Discussionsupporting
confidence: 88%
See 3 more Smart Citations
“…On the other hand, the penumbrae formed by the leaf sides (along the Y ‐axis) were wider on the +Y sides of the leaves than they were on the −Y sides. This asymmetry was regarded as resulting from the leaf bank tilt 24. These penumbra width results are similar to those reported by Fürweger et al24 Furthermore, although the discrepancies between the measured and calculated widths of the X ‐axis penumbrae were relatively small (maximum, 0.3 mm), those between the measured and calculated widths of the Y ‐axis penumbrae were large (maximum, 0.7 mm) when the MLC was used.…”
Section: Discussionsupporting
confidence: 88%
“…This asymmetry was regarded as resulting from the leaf bank tilt 24. These penumbra width results are similar to those reported by Fürweger et al24 Furthermore, although the discrepancies between the measured and calculated widths of the X ‐axis penumbrae were relatively small (maximum, 0.3 mm), those between the measured and calculated widths of the Y ‐axis penumbrae were large (maximum, 0.7 mm) when the MLC was used. On the other hand, the discrepancies resulting from using the fixed and variable collimators were within 0.1 mm.…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…The recently released CyberKnife® M6™ system is now equipped with multi-leaf collimator (InCise 2™) [15-16], which is reported to be more efficient in treating larger targets with fewer monitor units and less treatment time [17-19]. Linac-based SABR with gated VMAT delivery and a very high dose rate (flattening filter free) has also been implemented in the past several years.…”
Section: Introductionmentioning
confidence: 99%