2019
DOI: 10.1007/s12011-019-01891-4
|View full text |Cite
|
Sign up to set email alerts
|

Challenges in the Measurement and Interpretation of Serum Titanium Concentrations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 29 publications
1
3
0
1
Order By: Relevance
“…Our assessment of Ti concentrations using ICP-MS rather than inductively coupled plasma-optical emission spectroscopy (ICP-OES) is in accordance with current recommendations [29]. Our data description uses medians and statistical inference is based on non-parametric methods, which also complies with recommendations on the interpretation of Ti measurements that are referred to above.…”
Section: Strengths and Weaknesses Of This Studysupporting
confidence: 53%
“…Our assessment of Ti concentrations using ICP-MS rather than inductively coupled plasma-optical emission spectroscopy (ICP-OES) is in accordance with current recommendations [29]. Our data description uses medians and statistical inference is based on non-parametric methods, which also complies with recommendations on the interpretation of Ti measurements that are referred to above.…”
Section: Strengths and Weaknesses Of This Studysupporting
confidence: 53%
“…In this longitudinal study, at T0, the mean serum level of titanium observed were higher than the reference range set by mayo laboratories (< than 1 ng/L). 33 However actual numerical values cannot be compared because of differences in metallurgy, methods of analysis, and measurement units. The reasons for raised values may be attributed to dietary supplements, cosmetics, environment, water contamination due to industrial wastes, and occupation.…”
Section: Discussionmentioning
confidence: 99%
“…All patients provided consent to participate and had a blood draw (60 mL) for measurement of chromium, cobalt, titanium concentrations, inflammatory markers (C reactive protein [CRP], interleukin 6 [IL 6] and tumor necrosis factor alpha [TNF]) and systemic distribution of immune cells. Metal concentrations were assayed using inductively-coupled plasma mass spectrometry (ICP-MS) within an International Organization for Standardization Class-7 cleanroom in the Metals Laboratory ( 9 , 10 ). Whole blood cobalt and chromium concentrations were measured using ICP-MS. Serum titanium was measured using Triple-Quadrupole ICP-MS.…”
Section: Methodsmentioning
confidence: 99%