1998
DOI: 10.1002/(sici)1099-1581(1998100)9:10/11<786::aid-pat804>3.3.co;2-x
|Get access via publisher |Summarize |Cite
Carrier‐bound platinum and iron compounds with carcinostatic properties
Search citation statements
Paper Sections
Select...
11
10
8
0
Citation Types
3
34
0
0
Year Published
2000
2017
Publication Types
Select...
23
1
Relationship
1
23
Authors
Journals
Cited by 24 publications
(37 citation statements)
References 0 publications
3
34
0
0
“…The weight average molecular weight of PBI prepared by melt condensation (
…”$\overline M _{\rm w}$ = 27.200 g · mol −1 ) was found to be higher than that of PBI prepared by solution polycondensation ($\overline M _{\rm w}$ = 7.100 g · mol −1 ). This is in accordance with reports on higher end group reactivity in the melt 14Section: Resultssupporting
confidence: 94%
“…The weight average molecular weight of PBI prepared by melt condensation (
…”$\overline M _{\rm w}$ = 27.200 g · mol −1 ) was found to be higher than that of PBI prepared by solution polycondensation ($\overline M _{\rm w}$ = 7.100 g · mol −1 ). This is in accordance with reports on higher end group reactivity in the melt 14Section: Resultssupporting
confidence: 94%
“…The T g of PBI polymers are generally very high and varies from 350 to 450 °C depending on the backbone structure. 2,3,42 The T g obtained in this study for all Py-PBI polymers also fall in this range (Table 3 and Figure 4) attributing that these are high T g polymers. Generally the para connected PBI displays lower T g than the meta PBI.…”
Section: ■ Results and Discussionsupporting
confidence: 57%
“…The T g of PBI polymers are generally very high and varies from 350 to 450 °C depending on the backbone structure. ,, The T g obtained in this study for all Py-PBI polymers also fall in this range (Table and Figure ) attributing that these are high T g polymers. Generally the para connected PBI displays lower T g than the meta PBI. , The T g values differ from polymer to polymer depending on the DCA structure used for making the Py-PBI. The T g of the TPA polymer (397 °C, obtained from tan δ) is lowest among all the polymers.…”
Section: Resultssupporting
confidence: 53%
“…A higher value of IV indicates a higher molecular weight of the polymer 39. The quantification of the PBI molecular weight by the measurement of IV in H 2 SO 4 has been demonstrated in the literature extensively 16, 38. Figure 1 shows that IV increased with the initial monomer concentration increasing up to 4%, and then IV saturated and finally dropped at a very high initial monomer concentration (5.5%).…”
Section: Resultsmentioning
confidence: 69%
