2014
DOI: 10.1053/j.semnuclmed.2014.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac PET Perfusion Tracers: Current Status and Future Directions

Abstract: Positron emission tomography (PET) myocardial perfusion imaging (MPI) is increasingly used for non-invasive detection and evaluation of coronary artery disease (CAD). However, the widespread use of PET MPI has been limited by shortcomings of the current PET perfusion tracers. Availability of these tracers is limited by need for an on-site (15O water and 13N ammonia) or nearby (13N ammonia) cyclotron or commitment to costly generators (82Rb). Due to short half-lives ranging from 76sec for 82Rb, to 2.1min for 15… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
95
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 125 publications
(100 citation statements)
references
References 57 publications
3
95
0
2
Order By: Relevance
“…The ability of 13 NH 3 to provide separate subendocardial and subepicardial MBF values allowing transmural MBF analysis could have important clinical consequences given the importance of expanding the role of PET measurements and the various advantages that 13 NH 3 has in clinical practice [2][3][4]. Of the other available tracers, 82 Rb would probably have major limitations in spatial resolution for transmural measurements because of the relatively long distance covered by its high-energy positrons [33]. Because it is labelled with 18 F, flurpiridaz could possibly be more promising for this purpose, although the definition and validation of convincing models for MBF quantitation are still to be completed [34].…”
Section: Discussionmentioning
confidence: 99%
“…The ability of 13 NH 3 to provide separate subendocardial and subepicardial MBF values allowing transmural MBF analysis could have important clinical consequences given the importance of expanding the role of PET measurements and the various advantages that 13 NH 3 has in clinical practice [2][3][4]. Of the other available tracers, 82 Rb would probably have major limitations in spatial resolution for transmural measurements because of the relatively long distance covered by its high-energy positrons [33]. Because it is labelled with 18 F, flurpiridaz could possibly be more promising for this purpose, although the definition and validation of convincing models for MBF quantitation are still to be completed [34].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, higher myocardial extraction facilitates detection of milder perfusion defects Higuchi et al 18 makes it an optimal candidate for absolute MBF quantitation (5). In a rat biodistribution study, heart-to-lung and heart-toliver ratios of 18 F-Flurpiridaz were significantly higher than that of 99m Tc-sestamibi SPECT (17).…”
Section: The Highest Spatial Resolutionmentioning
confidence: 99%
“…The positron range before annihilation is 8.6 mm for 82 Rb, 4.1 mm for 15 O, 2.5 mm for 13 N, and 1 mm for 18 F leading to spatial resolution greater than the 5-7 mm that is usually quoted for PET. 16 In practice the resolution of a 82 Rb image is no better than that of 99m Tc or 201 Tl images acquired using a solid-state camera (see Figure 1).…”
Section: How Do the Imaging Characteristics Of 82 Rb Compare With Thomentioning
confidence: 99%