2021
DOI: 10.1016/j.trac.2021.116277
|View full text |Cite
|
Sign up to set email alerts
|

Calibration-free potentiometric sensing with solid-contact ion-selective electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
80
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 102 publications
(97 citation statements)
references
References 180 publications
0
80
0
Order By: Relevance
“…With the introduction of the Gr layer, the potential drifts were dramatically diminished. This may be attributed to the enhanced adhesion by the intermixed layer’s formation between the Gr contact and the ISM due to its hydrophobicity, as has been pointed out recently that hydrophobic effects play a crucial role in the minimization of potential drift( He et al, 2017 ; Nayak et al, 2017 ; Rousseau and Bühlmann, 2021 ). The surface characterization of both Cu/ISM and modified Cu/Gr/ISM interfaces was performed by electrochemical impedance spectroscopy ( Supplementary information section S-3 , Figure S-2) .…”
Section: Resultsmentioning
confidence: 94%
“…With the introduction of the Gr layer, the potential drifts were dramatically diminished. This may be attributed to the enhanced adhesion by the intermixed layer’s formation between the Gr contact and the ISM due to its hydrophobicity, as has been pointed out recently that hydrophobic effects play a crucial role in the minimization of potential drift( He et al, 2017 ; Nayak et al, 2017 ; Rousseau and Bühlmann, 2021 ). The surface characterization of both Cu/ISM and modified Cu/Gr/ISM interfaces was performed by electrochemical impedance spectroscopy ( Supplementary information section S-3 , Figure S-2) .…”
Section: Resultsmentioning
confidence: 94%
“…One is the potential stability and/or reproducibility caused by the ultrathin water layer and interfacial capacitance between solid contact and ISM [17][18][19][20]. Numerous efforts have been devoted to improving the properties of SC materials (such as hydrophobicity and redox capacitance with defined phase boundary potential) to address these issues [19][20][21][22][23][24][25]. The other is the leaking of ISM components leading to biological toxicity [26], particularly for medical applications.…”
Section: Introductionmentioning
confidence: 99%
“…The invention of solid-contact ion-selective electrodes has opened an avenue covering fabrication, application, and theory in ion-sensor technology [ 1 , 2 , 3 , 4 , 5 , 6 ]. The reference electrode, a counterpart in electrochemical measurement, was initially treated as an issue of its own.…”
Section: Introductionmentioning
confidence: 99%